The DOI matches its Crossref record.
Phosphorescent Oxygen Sensor with Dendritic Protection and Two-Photon Absorbing Antenna
Open accessAbstract
Imaging oxygen in 3D with submicron spatial resolution can be made possible by combining phosphorescence quenching technique with multiphoton laser scanning microscopy. Because Pt and Pd porphyrin-based phosphorescent dyes, traditionally used as phosphors in biological oxygen measurements, exhibit extremely low two-photon absorption (2PA) cross-sections, we designed a nanosensor for oxygen, in which a 2P absorbing antenna is coupled to a metalloporphyrin core via intramolecular energy transfer (ET) with the purpose of amplifying the 2PA induced phosphorescence of the metalloporphyrin. The central component of the device is a polyfunctionalized Pt porphyrin, whose triplet state emission at ambient temperatures is strong, occurs in the near infrared and is sensitive to O2. The 2PA chromophores are chosen in such a way that their absorption is maximal in the near infrared (NIR) window of tissue (e.g., 700-900 nm), while their fluorescence is overlapped with the absorption band(s) of the core metalloporphyrin, ensuring an efficient antenna-core resonance ET. The metalloporphyrin-antenna construct is embedded inside the protecting dendritic jacket, which isolates the core from interactions with biological macromolecules, controls diffusion of oxygen and makes the entire sensor water-soluble. Several Pt porphyrin-coumarin based sensors were synthesized and their photophyics studied to evaluate the proposed design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Designing dendrimers for biological applications
Lee, C. C., MacKay, J. A., Fréchet, J. M. J., & Szoka, F. C. (2005) · Nature Biotechnology · doi:10.1038/nbt1171 · Cited by 2,043
Recent Strategies to Develop Innovative Photosensitizers for Enhanced Photodynamic Therapy
Pham, T. C., Nguyen, V.-N., Choi, Y., Lee, S., & Yoon, J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00381 · Cited by 1,813
A review of NIR dyes in cancer targeting and imaging
Luo, S., Zhang, E., Su, Y., Cheng, T., & Shi, C. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.06.024 · Cited by 1,432
Optical methods for sensing and imaging oxygen: materials, spectroscopies and applications
Wang, X.-D., & Wolfbeis, O. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00039k · Cited by 1,114
Biological detection by optical oxygen sensing
Papkovsky, D. B., & Dmitriev, R. I. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60131e · Cited by 444
van Dongen, S. F. M., de Hoog, H.-P. M., Peters, R. J. R. W., Nallani, M., Nolte, R. J. M., & van Hest, J. C. M. (2009) · Chemical Reviews · doi:10.1021/cr900072y · Cited by 386
Zhang, S., Hosaka, M., Yoshihara, T., Negishi, K., Iida, Y., Tobita, S., & Takeuchi, T. (2010) · Cancer Research · doi:10.1158/0008-5472.can-09-3948 · Cited by 349
Dendrimers Derived from 1 → 3 Branching Motifs
Newkome, G. R., & Shreiner, C. (2010) · Chemical Reviews · doi:10.1021/cr900341m · Cited by 347
Dendrimer Porphyrins and Phthalocyanines
Li, W.-S., & Aida, T. (2009) · Chemical Reviews · doi:10.1021/cr900186c · Cited by 305
Metadata
- Authors
- Briñas, R. P., Troxler, T., Hochstrasser, R. M., & Vinogradov, S. A.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-07-28
- Volume
- 127
- Issue
- 33
- Pages
- 11851-11862
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2071160492
- Cited by
- 267
- References
- 0
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.