The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A Sensitized Europium Complex Generated by Micromolar Concentrations of Copper(I): Toward the Detection of Copper(I) in Biology
Abstract
Formation of a luminescent device by the Huisgen 1,3-dipolar cycloaddition reaction between a Eu(III) complex and dansyl azide is reported. This reaction is catalyzed by a common biological copper(I) complex [GS--Cu(I)], and the resultant copper(I) catalytic sensor shows a 10-fold enhancement of europium luminescence emission.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neurodegenerative diseases and oxidative stress
Barnham, K. J., Masters, C. L., & Bush, A. I. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1330 · Cited by 3,683
Effects of Angiogenesis Inhibitors on Multistage Carcinogenesis in Mice
Bergers, G., Javaherian, K., Lo, K.-M., Folkman, J., & Hanahan, D. (1999) · Science · doi:10.1126/science.284.5415.808 · Cited by 988
Cited by
Metals in Neurobiology: Probing Their Chemistry and Biology with Molecular Imaging
Que, E. L., Domaille, D. W., & Chang, C. J. (2008) · Chemical Reviews · doi:10.1021/cr078203u · Cited by 2,061
Reaction-based small-molecule fluorescent probes for chemoselective bioimaging
Chan, J., Dodani, S. C., & Chang, C. J. (2012) · Nature Chemistry · doi:10.1038/nchem.1500 · Cited by 1,883
Lanthanide Probes for Bioresponsive Imaging
Heffern, M. C., Matosziuk, L. M., & Meade, T. J. (2014) · Chemical Reviews · doi:10.1021/cr400477t · Cited by 1,202
Metal coordination in photoluminescent sensing
Liu, Z., He, W., & Guo, Z. (2013) · Chemical Society Reviews · doi:10.1039/c2cs35363f · Cited by 800
Colorimetric Biosensing Using Smart Materials
Song, Y., Wei, W., & Qu, X. (2011) · Advanced Materials · doi:10.1002/adma.201101853 · Cited by 666
Metadata
- Authors
- Viguier, R. F. H., & Hulme, A. N.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-08-10
- Volume
- 128
- Issue
- 35
- Pages
- 11370-11371
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2087183358
- Cited by
- 224
- References
- 2
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.