The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Gadolinium-Based Hybrid Nanoparticles as a Positive MR Contrast Agent
Abstract
A new nanoparticulate inorganic-organic hybrid-type positive contrast agent (CA), PGP/dextran-K01, was synthesized based on a GdPO4 inorganic core as a relaxation-time-shortening moiety and a dextran-coating, which generates monodispersibility in water, a high relaxation-time-shortening effect by retaining a large number of water molecules in proximity of the core and toxicity reduction in in-vivo studies. This PGP/dextran-K01 nanoparticle has high r1 and r2 values and a significantly low r2/r1 value, 1.1, which is unprecedented and which is the lowest value among existing nanoparticulate CAs indicating that PGP/dextran-K01 is a positive contrast agent. Because of this low r2/r1 value and the nanoparticulate shape, PGP/dextran-K01 will be a useful clinical substitute for negative CAs based on iron oxides.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hamm, B., Staks, T., Taupitz, M., Maibauer, R., Speidel, A., Huppertz, A., Frenzel, T., Lawaczeck, R., Wolf, K. J., & Lange, L. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040508 · Cited by 187
Liver MR imaging with iron oxides: toward consensus and clinical practice
Weissleder, R. (1994) · Radiology · doi:10.1148/radiology.193.3.7972790 · Cited by 101
Cited by
Nanomaterials for Theranostics: Recent Advances and Future Challenges
Lim, E.-K., Kim, T., Paik, S., Haam, S., Huh, Y.-M., & Lee, K. (2015) · Chemical Reviews · doi:10.1021/cr300213b · Cited by 1,233
Biological Applications of Rare-Earth Based Nanoparticles
Bouzigues, C., Gacoin, T., & Alexandrou, A. (2011) · ACS Nano · doi:10.1021/nn202378b · Cited by 598
Park, Y. I., Kim, J. H., Lee, K. T., Jeon, K., Na, H. B., Yu, J. H., Kim, H. M., Lee, N., Choi, S. H., Baik, S., et al. (2009) · Advanced Materials · doi:10.1002/adma.200901356 · Cited by 585
Zhou, J., Sun, Y., Du, X., Xiong, L., Hu, H., & Li, F. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.040 · Cited by 548
Exceedingly small iron oxide nanoparticles as positive MRI contrast agents
Wei, H., Bruns, O. T., Kaul, M. G., Hansen, E. C., Barch, M., Wiśniowska, A., Chen, O., Chen, Y., Li, N., Okada, S., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1620145114 · Cited by 489
Luminescent rare earth nanomaterials for bioprobe applications
Shen, J., Sun, L.-D., & Yan, C.-H. (2008) · Dalton Transactions · doi:10.1039/b805306e · Cited by 425
Size-Tunable, Ultrasmall NaGdF4 Nanoparticles: Insights into Their T1 MRI Contrast Enhancement
Johnson, N. J. J., Oakden, W., Stanisz, G. J., Scott Prosser, R., & van Veggel, F. C. J. M. (2011) · Chemistry of Materials · doi:10.1021/cm201297x · Cited by 414
Multifunctional nanoprobes for upconversion fluorescence, MR and CT trimodal imaging
Xing, H., Bu, W., Zhang, S., Zheng, X., Li, M., Chen, F., He, Q., Zhou, L., Peng, W., Hua, Y., et al. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.10.039 · Cited by 408
Hu, F., Jia, Q., Li, Y., & Gao, M. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/24/245604 · Cited by 147
Metadata
- Authors
- Hifumi, H., Yamaoka, S., Tanimoto, A., Citterio, D., & Suzuki, K.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-11-01
- Volume
- 128
- Issue
- 47
- Pages
- 15090-15091
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1991689498
- Cited by
- 239
- References
- 2
- FWCI
- 6.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.