The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Generation and Reactions of o-Bromophenyllithium without Benzyne Formation Using a Microreactor
Abstract
Microflow systems were found to serve as powerful tools for mechanistic studies on reactions involving highly unstable intermediates such as o -bromophenyllithium, which is known to decompose to benzyne very quickly even at −78 °C. Precise residence time control and precise temperature control of microsystems are responsible. Based on the information thus obtained, the Br−Li exchange reaction of o -dibromobenzene followed by reactions with electrophiles without benzyne formation was achieved using a microflow system. Sequential use of two bromine atoms in o -dibromobenzene with Br−Li exchange reactions followed by the reactions with electrophiles using the microsystem consisting of four micromixers and four microtube reactors was also accomplished.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Micro reactors: principles and applications in organic synthesis
Fletcher, P. D. I., Haswell, S. J., Pombo-Villar, E., Warrington, B. H., Watts, P., Wong, S. Y. F., & Zhang, X. (2002) · Tetrahedron · doi:10.1016/s0040-4020(02)00432-5 · Cited by 468
Room‐Temperature Swern Oxidations by Using a Microscale Flow System
Kawaguchi, T., Miyata, H., Ataka, K., Mae, K., & Yoshida, J. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200462466 · Cited by 227
Self-citationIwasaki, T., & Yoshida, J.-I. (2005) · Macromolecules · doi:10.1021/ma048369m · Cited by 224
Self-citationCation Pool-Initiated Controlled/Living Polymerization Using Microsystems
Nagaki, A., Kawamura, K., Suga, S., Ando, T., Sawamoto, M., & Yoshida, J.-I. (2004) · Journal of the American Chemical Society · doi:10.1021/ja044879k · Cited by 211
Self-citationSchwalbe, T., Autze, V., Hohmann, M., & Stirner, W. (2004) · Organic Process Research & Development · doi:10.1021/op049970n · Cited by 133
Cited by
Flow Chemistry: Recent Developments in the Synthesis of Pharmaceutical Products
Porta, R., Benaglia, M., & Puglisi, A. (2016) · Organic Process Research & Development · doi:10.1021/acs.oprd.5b00325 · Cited by 886
Taming hazardous chemistry by continuous flow technology
Movsisyan, M., Delbeke, E. I. P., Berton, J. K. E. T., Battilocchio, C., Ley, S. V., & Stevens, C. V. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00902b · Cited by 692
Flash Chemistry: Fast Chemical Synthesis by Using Microreactors
Yoshida, J., Nagaki, A., & Yamada, T. (2008) · Chemistry – A European Journal · doi:10.1002/chem.200800582 · Cited by 537
Self-citationMicrochemical systems for continuous-flow synthesis
Hartman, R. L., & Jensen, K. F. (2009) · Lab on a Chip · doi:10.1039/b906343a · Cited by 508
Flash chemistry: flow chemistry that cannot be done in batch
Yoshida, J.-I., Takahashi, Y., & Nagaki, A. (2013) · Chem. Commun. · doi:10.1039/c3cc44709j · Cited by 450
Self-citation
Metadata
- Authors
- Usutani, H., Tomida, Y., Nagaki, A., Okamoto, H., Nokami, T., & Yoshida, J.-I.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-02-27
- Volume
- 129
- Issue
- 11
- Pages
- 3046-3047
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2020338350
- Cited by
- 267
- References
- 5
- FWCI
- 17.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.