Microchemical systems for continuous-flow synthesis
Abstract
Microchemical systems have evolved rapidly over the last decade with extensive chemistry applications. Such systems enable discovery and development of synthetic routes while simultaneously providing increased understanding of underlying pathways and kinetics. We review basic trends and aspects of microsystems as they relate to continuous-flow microchemical synthesis. Key literature reviews are summarized and principles governing different microchemical operations discussed. Current trends and limitations of microfabrication, micromixing, chemical synthesis in microreactors, continuous-flow separations, multi-step synthesis, and integration of analytics are delineated. We conclude by summarizing the major challenges and outlook related to these topics.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Rational Development of Practical Catalysts for Aromatic Carbon−Nitrogen Bond Formation
Wolfe, J. P., Wagaw, S., Marcoux, J.-F., & Buchwald, S. L. (1998) · Accounts of Chemical Research · doi:10.1021/ar9600650 · Cited by 1,791
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708
Nguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Control and detection of chemical reactions in microfluidic systems
deMello, A. J. (2006) · Nature · doi:10.1038/nature05062 · Cited by 1,495
Micromixers—a review on passive and active mixing principles
Hessel, V., Löwe, H., & Schönfeld, F. (2005) · Chemical Engineering Science · doi:10.1016/j.ces.2004.11.033 · Cited by 1,479
Chemistry in Microstructured Reactors
Jähnisch, K., Hessel, V., Löwe, H., & Baerns, M. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200300577 · Cited by 1,286
Research works printed but not linked: 8
- Chevalier, 2008, Chim. Oggi-Chem. Today, 26, 6
- Kikutani, 2003, Lab Chip, 3, 51
- Zhang, 2006, Chim. Oggi-Chem. Today, 24, 43
- Hessel, 2006, Abstr. Pap. Am. Chem. Soc., 231, 312
- Fukuyama, 2008, Synlett, 151
- Baxendale, 2006, Ernst Schering Found Symp. Proc., 151
- Mennecke, 2008, Synthesis, 1589
- Baxendale, 2006, Synlett, 427
Cited by
The Hitchhiker’s Guide to Flow Chemistry
Plutschack, M. B., Pieber, B., Gilmore, K., & Seeberger, P. H. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00183 · Cited by 1,995
The past, present and potential for microfluidic reactor technology in chemical synthesis
Elvira, K. S., i Solvas, X. C., Wootton, R. C. R., & deMello, A. J. (2013) · Nature Chemistry · doi:10.1038/nchem.1753 · Cited by 1,203
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Deciding Whether To Go with the Flow: Evaluating the Merits of Flow Reactors for Synthesis
Hartman, R. L., McMullen, J. P., & Jensen, K. F. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201004637 · Cited by 999
Self-citationSynthesis of micro and nanostructures in microfluidic systems
Marre, S., & Jensen, K. F. (2010) · Chemical Society Reviews · doi:10.1039/b821324k · Cited by 734
Self-citation
Metadata
- Authors
- Hartman, R. L., & Jensen, K. F.
- Affiliations
- Massachusetts Institute of Technology (US)
- Corresponding author
- Jensen, Klavs F.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 17
- Pages
- 2495
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2071785669
- Cited by
- 508
- References
- 125
- Citations by year
- 2026: 10 · 2025: 13 · 2024: 11 · 2023: 11 · 2022: 15 · 2021: 8 · 2020: 26 · 2019: 33 · 2018: 28 · 2017: 34 · 2016: 46 · 2015: 37 · 2014: 41 · 2013: 41 · 2012: 58
- FWCI
- 30.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemistry › Organic Chemistry › Microwave-Assisted Synthesis and Applications
- Keywords
- microchemical systems, flow chemistry, microreactors, microfabrication, micromixing, continuous flow separation, multistep synthesis, reaction kinetics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microchemical systems for continuous-flow synthesis. https://app.cochat.ai/papers/10.1039/b906343a
- The paper
- Hartman, R. L., & Jensen, K. F. (2009). Microchemical systems for continuous-flow synthesis. Lab on a Chip. https://doi.org/10.1039/b906343a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.