The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Detection of Explosives with a Fluorescent Nanofibril Film
Abstract
A new type of fluorescence sensory material has been developed from an alkoxycarbonyl-substituted carbazole-cornered tetracycle. Films fabricated from such materials are shown to be efficient in detecting explosive vapor, probably owing to the extended 1D molecular stacking between the component molecules and intrinsic nanoporous morphology thus formed within the film. The former facilitates long-range exciton migration, while the latter favors adsorption and diffusion of gaseous adsorbates within the film. A combination of these two characteristics enables efficient fluorescence quenching of the film by gaseous quenchers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Conjugated Polymer-Based Chemical Sensors
McQuade, D. T., Pullen, A. E., & Swager, T. M. (2000) · Chemical Reviews · doi:10.1021/cr9801014 · Cited by 3,718
Handbook of Fluorescence Spectra of Aromatic Molecules
(1971) · Elsevier eBooks · doi:10.1016/b978-0-12-092656-5.x5001-1 · Cited by 2,335
Light-induced shape-memory polymers
Lendlein, A., Jiang, H., Jünger, O., & Langer, R. (2005) · Nature · doi:10.1038/nature03496 · Cited by 2,006
Sensitivity gains in chemosensing by lasing action in organic polymers
Rose, A., Zhu, Z., Madigan, C. F., Swager, T. M., & Bulović, V. (2005) · Nature · doi:10.1038/nature03438 · Cited by 778
Hoffmann, M., Schmidt, K., Fritz, T., Hasche, T., Agranovich, V. M., & Leo, K. (2000) · Chemical Physics · doi:10.1016/s0301-0104(00)00157-9 · Cited by 234
Peer Reviewed: Detection of Explosives by Electronic Noses
Yinon, J. (2003) · Analytical Chemistry · doi:10.1021/ac0312460 · Cited by 210
Cited by
Fluorescence based explosive detection: from mechanisms to sensory materials
Sun, X., Wang, Y., & Lei, Y. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00496a · Cited by 1,243
Lan, A., Li, K., Wu, H., Olson, D. H., Emge, T. J., Ki, W., Hong, M., & Li, J. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200804853 · Cited by 1,237
Zang, L., Che, Y., & Moore, J. S. (2008) · Accounts of Chemical Research · doi:10.1021/ar800030w · Cited by 1,199
Self-citationOptical explosives detection: from color changes to fluorescence turn-on
Germain, M. E., & Knapp, M. J. (2009) · Chemical Society Reviews · doi:10.1039/b809631g · Cited by 1,046
Kim, F. S., Ren, G., & Jenekhe, S. A. (2011) · Chemistry of Materials · doi:10.1021/cm102772x · Cited by 664
Nanosensors for trace explosive detection
Senesac, L., & Thundat, T. G. (2008) · Materials Today · doi:10.1016/s1369-7021(08)70017-8 · Cited by 368
Tailoring Electronic Properties of Graphene by π–π Stacking with Aromatic Molecules
Zhang, Z., Huang, H., Yang, X., & Zang, L. (2011) · The Journal of Physical Chemistry Letters · doi:10.1021/jz201273r · Cited by 304
Self-citationZhang, S., Du, D., Qin, J., Bao, S., Li, S., He, W., Lan, Y., Shen, P., & Su, Z. (2014) · Chemistry – A European Journal · doi:10.1002/chem.201304692 · Cited by 288
Maggini, L., & Bonifazi, D. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15031f · Cited by 269
Dong, W., Pina, J., Pan, Y., Preis, E., Seixas de Melo, J. S., & Scherf, U. (2015) · Polymer · doi:10.1016/j.polymer.2015.08.064 · Cited by 36
Metadata
- Authors
- Naddo, T., Che, Y., Zhang, W., Balakrishnan, K., Yang, X., Yen, M., Zhao, J., Moore, J. S., & Zang, L.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-05-15
- Volume
- 129
- Issue
- 22
- Pages
- 6978-6979
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1965907988
- Cited by
- 397
- References
- 6
- FWCI
- 13.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.