An Electron-Conducting Cross-Linked Polyaniline-Based Redox Hydrogel, Formed in One Step at pH 7.2, Wires Glucose Oxidase
The DOI matches its Crossref record.
Abstract
A polyaniline-based, electron-conducting, glucose-permeable, redox hydrogel was formed in one step at pH 7.2 by cross-linking polymer acid-templated polyaniline with a water-soluble diepoxide, poly(ethylene glycol diglycidyl ether). Coimmobilization of glucose oxidase in the hydrogel, by co-cross-linking in the same step, led to the electrical wiring of the enzyme and to the formation of a glucose electrooxidation catalyst, allowing the electrocatalytic oxidation of glucose at a steady-state current density of 225 μA·cm -2 at 0.3 V vs Ag/AgCl.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Self-citationHierarchical nanostructured conducting polymer hydrogel with high electrochemical activity
Pan, L., Yu, G., Zhai, D., Lee, H. R., Zhao, W., Liu, N., Wang, H., Tee, B. C.-K., Shi, Y., Cui, Y., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1202636109 · Cited by 1,216
“To date, the synthetic routes toward conducting polymer hydrogels include synthesizing a conducting polymer monomer within a nonconducting hydrogel matrix (8, 9) using multivalent metal ions (Fe3þ or Mg2þ) to crosslink poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) (10, 11) and using nonconducting…”
MethodLu, B., Yuk, H., Lin, S., Jian, N., Qu, K., Xu, J., & Zhao, X. (2019) · Nature Communications · doi:10.1038/s41467-019-09003-5 · Cited by 1,035
Recent advances in electrochemical glucose biosensors: a review
Chen, C., Xie, Q., Yang, D., Xiao, H., Fu, Y., Tan, Y., & Yao, S. (2013) · RSC Advances · doi:10.1039/c2ra22351a · Cited by 807
Hydrogel Based Sensors for Biomedical Applications: An Updated Review
Tavakoli, J., & Tang, Y. (2017) · Polymers · doi:10.3390/polym9080364 · Cited by 434
“Polyaniline-PEG Electrochemical N/A [249]”
Ultrahigh‐Conductivity Polymer Hydrogels with Arbitrary Structures
Yao, B., Wang, H., Zhou, Q., Wu, M., Zhang, M., Li, C., & Shi, G. (2017) · Advanced Materials · doi:10.1002/adma.201700974 · Cited by 423
Recent advances in designing conductive hydrogels for flexible electronics
Peng, Q., Chen, J., Wang, T., Peng, X., Liu, J., Wang, X., Wang, J., & Zeng, H. (2020) · InfoMat · doi:10.1002/inf2.12113 · Cited by 297
Nanostructured conducting polymers for energy applications: towards a sustainable platform
Ghosh, S., Maiyalagan, T., & Basu, R. N. (2016) · Nanoscale · doi:10.1039/c5nr08803h · Cited by 262
Hydrogel Actuators and Sensors for Biomedical Soft Robots: Brief Overview with Impending Challenges
Banerjee, H., Suhail, M., & Ren, H. (2018) · Biomimetics · doi:10.3390/biomimetics3030015 · Cited by 249
“01–8 mM [179] Polyaniline–PEG Electrochemical [180] PEG Optical RT: 10 min; LR: 0–600 mg/dL−1 [166] PVA–vinyl pyridine Electrochemical RT: 11 s [181] Chitosan Electrochemical RT: 7 s; LR: 5 μM to 2.”
Soft Bioelectronics Based on Nanomaterials
Cho, K. W., Sunwoo, S.-H., Hong, Y. J., Koo, J. H., Kim, J. H., Baik, S., Hyeon, T., & Kim, D.-H. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00531 · Cited by 244
Zou, Y., Zhang, Z., Zhong, W., & Yang, W. (2018) · Journal of Materials Chemistry A · doi:10.1039/c8ta01366g · Cited by 210
Elastic, Conductive, Polymeric Hydrogels and Sponges
Lu, Y., He, W., Cao, T., Guo, H., Zhang, Y., Li, Q., Shao, Z., Cui, Y., & Zhang, X. (2014) · Scientific Reports · doi:10.1038/srep05792 · Cited by 179
Rational design and applications of conducting polymer hydrogels as electrochemical biosensors
Li, L., Shi, Y., Pan, L., Shi, Y., & Yu, G. (2015) · Journal of Materials Chemistry B · doi:10.1039/c5tb00090d · Cited by 171
Soft bioelectronics for the management of cardiovascular diseases
Sunwoo, S.-H., Han, S. I., Park, C. S., Kim, J. H., Georgiou, J. S., Lee, S.-P., Kim, D.-H., & Hyeon, T. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00102-z · Cited by 167
“Conductive hydrogels are typically composed of conducting fillers that transport charges, such as conductive polymers (for example, PANI 51 , PPy 52 and PEDOT:PSS 53 ), metallic salts (for example, LiCl, Na + , Ca 2+ , Al 3+ , Fe 3+ , Tb 3+ and K + ) 54–60 , ionic liquids (for example, 1-ethyl-3-methylimidazolium chlo…”
InfluentialHe, J., Zhang, A., Zhang, Y., & Guan, Y. (2011) · Macromolecules · doi:10.1021/ma1029532 · Cited by 48
Metadata
- Authors
- Mano, N., Yoo, J. E., Tarver, J., Loo, Y.-L., & Heller, A.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-05-11
- Volume
- 129
- Issue
- 22
- Pages
- 7006-7007
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2005987758
- Cited by
- 126
- References
- 0
- FWCI
- 8.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.