Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 189

The DOI matches its Crossref record.

Electron Capture Dissociation Proceeds with a Low Degree of Intramolecular Migration of Peptide Amide Hydrogens

Rand, Kasper D., Adams, Christopher M., Zubarev, Roman A., Jørgensen, Thomas J. D.·2008·Journal of the American Chemical Society

Abstract

Hydrogen (1H/2H) exchange combined with mass spectrometry (HX-MS) has become a recognized method for the analysis of protein structural dynamics. Presently, the incorporated deuterons are typically localized by enzymatic cleavage of the labeled proteins and single residue resolution is normally only obtained for a few residues. Determination of site-specific deuterium levels by gas-phase fragmentation in tandem mass spectrometers would greatly increase the applicability of the HX-MS method. The biggest obstacle in achieving this goal is the intramolecular hydrogen migration (i.e., hydrogen scrambling) that occurs during vibrational excitation of gas-phase ions. Unlike traditional collisional ion activation, electron capture dissociation (ECD) is not associated with substantial vibrational excitation. We investigated the extent of intramolecular backbone amide hydrogen (1H/2H) migration upon ECD using peptides with a unique selective deuterium incorporation. Our results show that only limited amide hydrogen migration occurs upon ECD, provided that vibrational excitation prior to the electron capture event is minimized. Peptide ions that are excessively vibrationally excited in the electrospray ion source by, e.g., high declustering potentials or during precursor ion selection (via sideband excitation) in the external linear quadrupole ion trap undergo nearly complete hydrogen (1H/2H) scrambling. Similarly, collision-induced dissociation (CID) in the external linear quadrupole ion trap results in complete or extensive hydrogen (1H/2H) scrambling. This precludes the use of CID as a method to obtain site-specific information from proteins that are labeled in solution-phase 1H/2H exchange experiments. In contrast, the deuteration levels of the c- and z-fragment ions generated from ECD closely mimic the known solution deuteration pattern of the selectively labeled peptides. This excellent correlation between the results obtained from gas phase and solution suggests that ECD holds great promise as a general method to obtain single residue resolution in proteins from solution 1H/2H exchange experiments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja076448i

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Rand, K. D., Adams, C. M., Zubarev, R. A., & Jørgensen, T. J. D.
Venue
Journal of the American Chemical Society
Published
2008-01-03
Volume
130
Issue
4
Pages
1341-1349
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2084370050
Cited by
189
References
0
FWCI
6.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.