The DOI matches its Crossref record.
Aptamer-Based Optical Probes with Separated Molecular Recognition and Signal Transduction Modules
Abstract
A general strategy was developed to transform aptamers into highly sensitive and selective optical sensors. This was accomplished with an unmodified aptamer as the molecular recognition element and a competitor oligo, which was completely or partially complementary to the aptamer, as the signal transduction element. Displacement of competitor oligos in the presence of targets resulted in a detectable optical readout. Successful application of this strategy has been demonstrated not only with different types of targets (small molecules and proteins), but also with different types of aptamers (DNA and RNA). This strategy has high potential for various applications in high-throughput drug screening and intracellular studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Functional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
Zhou, W., Saran, R., & Liu, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00063 · Cited by 931
Applications of Aptamers as Sensors
Cho, E. J., Lee, J.-W., & Ellington, A. D. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112851 · Cited by 788
DNA-Mediated Homogeneous Binding Assays for Nucleic Acids and Proteins
Zhang, H., Li, F., Dever, B., Li, X.-F., & Le, X. C. (2013) · Chemical Reviews · doi:10.1021/cr300340p · Cited by 415
Aptamer binding assays for proteins: The thrombin example—A review
Deng, B., Lin, Y., Wang, C., Li, F., Wang, Z., Zhang, H., Li, X.-F., & Le, X. C. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.04.055 · Cited by 379
Optical aptasensors for quantitative detection of small biomolecules: A review
Feng, C., Dai, S., & Wang, L. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.03.014 · Cited by 300
Optical Thermophoresis for Quantifying the Buffer Dependence of Aptamer Binding
Baaske, P., Wienken, C. J., Reineck, P., Duhr, S., & Braun, D. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200903998 · Cited by 254
Nucleic acid-based fluorescent probes and their analytical potential
Juskowiak, B. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4304-5 · Cited by 252
Nanotechnology-based electrochemical sensors for biomonitoring chemical exposures
Barry, R. C., Lin, Y., Wang, J., Liu, G., & Timchalk, C. A. (2009) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2008.71 · Cited by 73
Metadata
- Authors
- Li, N., & Ho, C.-M.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-02-01
- Volume
- 130
- Issue
- 8
- Pages
- 2380-2381
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1978754949
- Cited by
- 221
- References
- 0
- FWCI
- 9.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.