The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Paramagnetic Relaxation-Based 19F MRI Probe To Detect Protease Activity
Abstract
A novel design principle for 19F MRI probes detecting protease activity was developed. This principle is based on 19F MRI signal quenching by the intramolecular paramagnetic effect from Gd3+. The intramolecular Gd3+ dramatically attenuated the 19F probe signal, and the paramagnetic effect was cancelled by the probe hydrolyzation by caspase-3. Using this probe, it was shown that the probe could detect caspase-3 activity spatially from a phantom image using 19F MRI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Combinatorial Approach Defines Specificities of Members of the Caspase Family and Granzyme B
Thornberry, N. A., Rano, T. A., Peterson, E. P., Rasper, D. M., Timkey, T., Garcia-Calvo, M., Houtzager, V. M., Nordstrom, P. A., Roy, S., Vaillancourt, J. P., et al. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.29.17907 · Cited by 2,068
In vivo visualization of gene expression using magnetic resonance imaging
Louie, A. Y., Hüber, M. M., Ahrens, E. T., Rothbächer, U., Moats, R., Jacobs, R. E., Fraser, S. E., & Meade, T. J. (2000) · Nature Biotechnology · doi:10.1038/73780 · Cited by 1,141
19F and 1H MRI detection of amyloid β plaques in vivo
Higuchi, M., Iwata, N., Matsuba, Y., Sato, K., Sasamoto, K., & Saido, T. C. (2005) · Nature Neuroscience · doi:10.1038/nn1422 · Cited by 339
Emerging concepts in molecular MRI
Sosnovik, D. E., & Weissleder, R. (2007) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2006.11.001 · Cited by 227
Functional MRI using molecular imaging agents
Jasanoff, A. (2005) · Trends in Neurosciences · doi:10.1016/j.tins.2004.12.007 · Cited by 50
Cited by
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Lanthanide Probes for Bioresponsive Imaging
Heffern, M. C., Matosziuk, L. M., & Meade, T. J. (2014) · Chemical Reviews · doi:10.1021/cr400477t · Cited by 1,202
19F Magnetic Resonance Imaging (MRI): From Design of Materials to Clinical Applications
Tirotta, I., Dichiarante, V., Pigliacelli, C., Cavallo, G., Terraneo, G., Bombelli, F. B., Metrangolo, P., & Resnati, G. (2015) · Chemical Reviews · doi:10.1021/cr500286d · Cited by 521
Advanced functional materials based on polyhedral oligomeric silsesquioxane (POSS)
Tanaka, K., & Chujo, Y. (2012) · J. Mater. Chem. · doi:10.1039/c1jm14231c · Cited by 489
Activity-Based Profiling of Proteases
Sanman, L. E., & Bogyo, M. (2014) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-060713-035352 · Cited by 330
Metadata
- Authors
- Mizukami, S., Takikawa, R., Sugihara, F., Hori, Y., Tochio, H., Wälchli, M., Shirakawa, M., & Kikuchi, K.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-12-23
- Volume
- 130
- Issue
- 3
- Pages
- 794-795
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2047424552
- Cited by
- 254
- References
- 5
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.