The DOI matches its Crossref record.
Polymerized PolyHEMA Photonic Crystals: pH and Ethanol Sensor Materials
Abstract
The surface of monodisperse silica particles synthesized using the Stober process were coated with a thin layer of polystyrene. Surface charge groups were attached by a grafting polymerization of styrene sulfonate. The resulting highly charged monodisperse silica particles self-assemble into crystalline colloidal arrays (CCA) in deionized water. We polymerized hydroxyethyl methacrylate (HEMA) around the CCA to form a HEMA-polymerized crystalline colloidal array (PCCA). Hydrofluoric acid was utilized to etch out the silica particles to produce a three-dimensional periodic array of voids in the HEMA PCCA. The diffraction from the embedded CCA sensitively monitors the concentration of ethanol in water because the HEMA PCCA shows a large volume dependence on ethanol due to a decreased Flory-Huggins mixing parameter. Between pure water and 40% ethanol the diffraction shifts across the entire visible spectral region. We accurately modeled the dependence of the diffraction wavelength on ethanol concentration using Flory theory. We also fabricated a PCCA (which responds to pH changes in both low and high ionic strength solutions) by utilizing a second polymerization to incorporate carboxyl groups into the HEMA PCCA. We were also able to model the pH dependence of diffraction of the HEMA PCCA by using Flory theory. An unusual feature of the pH response is a hysteresis in response to titration to higher and lower pH. This hysteresis results from the formation of a Donnan potential at high pH which shifts the ionic equilibrium. The kinetics of equilibration is very slow due to the ultralow diffusion constant of protons in the carboxylated PCCA as predicted earlier by the Tanaka group.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
High-efficiency perovskite–polymer bulk heterostructure light-emitting diodes
Zhao, B., Bai, S., Kim, V., Lamboll, R., Shivanna, R., Auras, F., Richter, J. M., Yang, L., Dai, L., Alsari, M., et al. (2018) · Nature Photonics · doi:10.1038/s41566-018-0283-4 · Cited by 886
Fiber-Optic Chemical Sensors and Biosensors (2015–2019)
Wang, X.-D., & Wolfbeis, O. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04708 · Cited by 833
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Thermochromic Polymers—Function by Design
Seeboth, A., Lötzsch, D., Ruhmann, R., & Muehling, O. (2014) · Chemical Reviews · doi:10.1021/cr400462e · Cited by 316
Bio-Inspired Structural Colors Produced via Self-Assembly of Synthetic Melanin Nanoparticles
Xiao, M., Li, Y., Allen, M. C., Deheyn, D. D., Yue, X., Zhao, J., Gianneschi, N. C., Shawkey, M. D., & Dhinojwala, A. (2015) · ACS Nano · doi:10.1021/acsnano.5b01298 · Cited by 295
Two-Dimensional Photonic Crystal Chemical and Biomolecular Sensors
Cai, Z., Smith, N. L., Zhang, J.-T., & Asher, S. A. (2015) · Analytical Chemistry · doi:10.1021/ac504679n · Cited by 216
Self-citation
Metadata
- Authors
- Xu, X., Goponenko, A. V., & Asher, S. A.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-02-14
- Volume
- 130
- Issue
- 10
- Pages
- 3113-3119
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2082096965
- Cited by
- 211
- References
- 0
- FWCI
- 8.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.