The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Oxygen Gas Sensing by Luminescence Quenching in Crystals of Cu(xantphos)(phen)+ Complexes
Abstract
We have shown that crystals of the highly emissive copper(I) compounds [Cu(POP)(dmp)]tfpb, [Cu(xantphos)(dmp)]tfpb, [Cu(xantphos)(dipp)]tfpb, and [Cu(xantphos)(dipp)]pftpb, (where POP = bis[2-(diphenylphosphino)phenyl]ether; xantphos = 4,5-bis(diphenylphosphino)-9,9-dimethylxanthene; dmp = 2,9-dimethyl-1,10-phenanthroline; dipp = 2,9-diisopropyl-1,10-phenanthroline (dipp); tfpb(-) = tetrakis(bis-3,5-trifluoromethylphenylborate); and pftpb = tetrakis(pentfluorophenyl)borate) are oxygen gas sensors. The sensing ability correlates with the amount of void space calculated from the crystal structures. The compounds exhibit linear Stern-Volmer plots with reproducible K(SV) constants from sample to sample; these results reinforce the observations that the sensing materials are crystalline and the sensing sites are homogeneous within the crystals. The long lifetime (∼30 μs), high emission quantum yield (ϕ = 0.66), appreciable K(SV) value (5.65), and very rapid response time (51 ms for the 95% return constant) for [Cu(xantphos)(dmp)]tfpb are significantly better than those for the [Cu(NN)(2)]tfpb complexes studied previously and compare favorably with [Ru(4,7-Me2phen)(3)](tfpb)(2), (K(SV) = 4.76; 4,7-Me(2)phen = 4,7-dimethyl-1,10- phenanthroline). The replacement of precious metals (like Ru or Pt) with copper may be technologically significant and the new compounds can be synthesized in one or two steps from commercially available starting materials. The strictly linear Stern-Volmer behavior observed for these systems and the absence of a polymer matrix that might cause variability in sensor to sensor sensitivity may allow a simple single-reference point calibration procedure, an important consideration for an inexpensive onetime limited use sensor that could be mass produced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Leventis, N., Elder, I. A., Rolison, D. R., Anderson, M. L., & Merzbacher, C. I. (1999) · Chemistry of Materials · doi:10.1021/cm9901966 · Cited by 163
Cited by
Optical methods for sensing and imaging oxygen: materials, spectroscopies and applications
Wang, X.-D., & Wolfbeis, O. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00039k · Cited by 1,114
Metal-complex chromophores for solar hydrogen generation
Yuan, Y.-J., Yu, Z.-T., Chen, D.-Q., & Zou, Z.-G. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00436a · Cited by 423
Zhang, Y., Schulz, M., Wächtler, M., Karnahl, M., & Dietzek, B. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.10.016 · Cited by 346
Copper(i)–iodide cluster structures as functional and processable platform materials
Troyano, J., Zamora, F., & Delgado, S. (2021) · Chemical Society Reviews · doi:10.1039/d0cs01470b · Cited by 266
Metadata
- Authors
- Smith, C. S., Branham, C. W., Marquardt, B. J., & Mann, K. R.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-09-20
- Volume
- 132
- Issue
- 40
- Pages
- 14079-14085
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2319119488
- Cited by
- 202
- References
- 1
- FWCI
- 6.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.