Ion Mobility Mass Spectrometry of Two Tetrameric Membrane Protein Complexes Reveals Compact Structures and Differences in Stability and Packing
Open accessThe DOI matches its Crossref record.
Abstract
Here we examined the gas-phase structures of two tetrameric membrane protein complexes by ion mobility mass spectrometry. The collision cross sections measured for the ion channel are in accord with a compact configuration of subunits, suggesting that the native-like structure can be preserved under the harsh activation conditions required to release it from the detergent micelle into the gas phase. We also found that the quaternary structure of the transporter, which has fewer transmembrane subunits than the ion channel, is less stable once stripped of detergents and bulk water. These results highlight the potential of ion mobility mass spectrometry for characterizing the overall topologies of membrane protein complexes and the structural changes associated with nucleotide, lipid, and drug binding.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lanucara, F., Holman, S. W., Gray, C. J., & Eyers, C. E. (2014) · Nature Chemistry · doi:10.1038/nchem.1889 · Cited by 901
Mass spectrometry of intact membrane protein complexes
Laganowsky, A., Reading, E., Hopper, J. T. S., & Robinson, C. V. (2013) · Nature Protocols · doi:10.1038/nprot.2013.024 · Cited by 409
Self-citationThe role of interfacial lipids in stabilizing membrane protein oligomers
Gupta, K., Donlan, J. A. C., Hopper, J. T. S., Uzdavinys, P., Landreh, M., Struwe, W. B., Drew, D., Baldwin, A. J., Stansfeld, P. J., & Robinson, C. V. (2017) · Nature · doi:10.1038/nature20820 · Cited by 401
Self-citationNative ion mobility-mass spectrometry and related methods in structural biology
Konijnenberg, A., Butterer, A., & Sobott, F. (2013) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2012.11.013 · Cited by 245
“The experimental CCS are in good correspondence with the calculated values (only 1% difference; 6900 and 6969 Å respectively) [98].”
BackgroundResultAdding a new separation dimension to MS and LC–MS: What is the utility of ion mobility spectrometry?
D'Atri, V., Causon, T., Hernandez‐Alba, O., Mutabazi, A., Veuthey, J., Cianferani, S., & Guillarme, D. (2018) · Journal of Separation Science · doi:10.1002/jssc.201700919 · Cited by 184
Advances in the Mass Spectrometry of Membrane Proteins: From Individual Proteins to Intact Complexes
Barrera, N. P., & Robinson, C. V. (2011) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-062309-093307 · Cited by 154
Self-citationKonijnenberg, A., Bannwarth, L., Yilmaz, D., Koçer, A., Venien‐Bryan, C., & Sobott, F. (2015) · Protein Science · doi:10.1002/pro.2703 · Cited by 45
“be correlated to the extent of their membrane spanning regions.(36) Furthermore, especially when strip-”
Background
Metadata
- Authors
- Wang, S. C., Politis, A., Di Bartolo, N., Bavro, V. N., Tucker, S. J., Booth, P. J., Barrera, N. P., & Robinson, C. V.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-10-15
- Volume
- 132
- Issue
- 44
- Pages
- 15468-15470
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1982231180
- Cited by
- 81
- References
- 0
- FWCI
- 3.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.