An Activity-Based Near-Infrared Glucuronide Trapping Probe for Imaging β-Glucuronidase Expression in Deep Tissues
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
β-glucuronidase is an attractive reporter and prodrug-converting enzyme. The development of near-IR (NIR) probes for imaging of β-glucuronidase activity would be ideal to allow estimation of reporter expression and for personalized glucuronide prodrug cancer therapy in preclinical studies. However, NIR glucuronide probes are not yet available. In this work, we developed two fluorescent probes for detection of β-glucuronidase activity, one for the NIR range (containing IR-820 dye) and the other for the visible range [containing fluorescein isothiocyanate (FITC)], by utilizing a difluoromethylphenol-glucuronide moiety (TrapG) to trap the fluorochromes in the vicinity of the active enzyme. β-glucuronidase-mediated hydrolysis of the glucuronyl bond of TrapG generates a highly reactive alkylating group that facilitates the attachment of the fluorochrome to nucleophilic moieties located near β-glucuronidase-expressing sites. FITC-TrapG was selectively trapped on purified β-glucuronidase or β-glucuronidase-expressing CT26 cells (CT26/mβG) but not on bovine serum albumin or non-β-glucuronidase-expressing CT26 cells used as controls. β-glucuronidase-activated FITC-TrapG did not interfere with β-glucuronidase activity and could label bystander proteins near β-glucuronidase. Both FITC-TrapG and NIR-TrapG specifically imaged subcutaneous CT26/mβG tumors, but only NIR-TrapG could image CT26/mβG tumors transplanted deep in the liver. Thus NIR-TrapG may provide a valuable tool for visualizing β-glucuronidase activity in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A clearer vision for in vivo imaging
Weissleder, R. (2001) · Nature Biotechnology · doi:10.1038/86684 · Cited by 3,839
Cited by
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Recent progresses in small-molecule enzymatic fluorescent probes for cancer imaging
Liu, H.-W., Chen, L., Xu, C., Li, Z., Zhang, H., Zhang, X.-B., & Tan, W. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00862g · Cited by 948
Successively activatable ultrasensitive probe for imaging tumour acidity and hypoxia
Zheng, X., Mao, H., Huo, D., Wu, W., Liu, B., & Jiang, X. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0057 · Cited by 210
Cellular-scale proximity labeling for recording cell spatial organization in mouse tissues
Zhang, X., Tang, Q., Sun, J., Guo, Y., Zhang, S., Liang, S., Dai, P., & Chen, X. (2023) · Science Advances · doi:10.1126/sciadv.adg6388 · Cited by 37
“QM has previously been used for monitoring enzyme activities in living mice ( 38 ), which indicates that QM, at proper concentrations, should be biocompatible for in vivo use.”
Metadata
- Authors
- Cheng, T.-C., Roffler, S. R., Tzou, S.-C., Chuang, K.-H., Su, Y.-C., Chuang, C.-H., Kao, C.-H., Chen, C.-S., Harn, I.-H., Liu, K.-Y., Cheng, T.-L., & Leu, Y.-L.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-02-01
- Volume
- 134
- Issue
- 6
- Pages
- 3103-3110
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1969317936
- Cited by
- 95
- References
- 1
- FWCI
- 2.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Activity-Based Near-Infrared Glucuronide Trapping Probe for Imaging β-Glucuronidase Expression in Deep Tissues. https://app.cochat.ai/papers/10.1021/ja209335z
- The paper
- Cheng, T.-C., Roffler, S. R., Tzou, S.-C., Chuang, K.-H., Su, Y.-C., Chuang, C.-H., Kao, C.-H., Chen, C.-S., Harn, I.-H., Liu, K.-Y., Cheng, T.-L., & Leu, Y.-L. (2012). An Activity-Based Near-Infrared Glucuronide Trapping Probe for Imaging β-Glucuronidase Expression in Deep Tissues. Journal of the American Chemical Society. https://doi.org/10.1021/ja209335z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.