A Physical Approach To Specifically Improve the Mobility of Alkane Liquid Drops
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Seamless control of resistance to liquid drop movement for polar (water) and nonpolar alkane (n-hexadecane, n-dodecane, and n-decane) probe liquids on substrate surfaces was successfully demonstrated using molten linear poly(dimethylsiloxane) (PDMS) brush films with a range of different molecular weights (MWs). The ease of movement of liquid drops critically depended on polymer chain mobility as it relates to both polymer MW and solvent swelling on these chemically- and topographically identical surfaces. Our brush films therefore displayed lower resistances to liquid drop movement with decreasing polymer MW and surface tension of probe liquid as measured by contact angle (CA) hysteresis and tilt angle measurements. Subsequently, while mobility of water drops was inferior and became worse at higher MWs, n-decane drops were found to experience little resistance to movement on these polymer brush films. Calculating CA hysteresis as Δθ(cos) = cos θ(R) - cos θ(A) (θ(A) and θ(R) are the advancing and receding CAs, respectively) rather than the standard Δθ = θ(A) - θ(R) was found to be advantageous for estimation of the actual dynamic dewetting behavior of various probe liquids on an inclined substrate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polyfluorinated Compounds: Past, Present, and Future
Lindstrom, A. B., Strynar, M. J., & Libelo, E. L. (2011) · Environmental Science & Technology · doi:10.1021/es2011622 · Cited by 1,628
Controlling polymer-surface interactions with random copolymer brushes
Mansky, P., Liu, Y., Huang, E., Russell, T. P., & Hawker, C. (1997) · Science · doi:10.1126/science.275.5305.1458 · Cited by 1,291
Lubrication by charged polymers
Raviv, U., Giasson, S., Kampf, N., Gohy, J.-F., Jérôme, R., & Klein, J. (2003) · Nature · doi:10.1038/nature01970 · Cited by 910
Reduction of frictional forces between solid surfaces bearing polymer brushes
Klein, J., Kumacheva, E., Mahalu, D., Perahia, D., & Fetters, L. J. (1994) · Nature · doi:10.1038/370634a0 · Cited by 615
Cited by
Omniphobic liquid-like surfaces
Chen, L., Huang, S., Ras, R. H. A., & Tian, X. (2023) · Nature Reviews Chemistry · doi:10.1038/s41570-022-00455-w · Cited by 297
Metadata
- Authors
- Cheng, D. F., Urata, C., Masheder, B., & Hozumi, A.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-06-11
- Volume
- 134
- Issue
- 24
- Pages
- 10191-10199
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2312413441
- Cited by
- 192
- References
- 4
- FWCI
- 4.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Physical Approach To Specifically Improve the Mobility of Alkane Liquid Drops. https://app.cochat.ai/papers/10.1021/ja302903e
- The paper
- Cheng, D. F., Urata, C., Masheder, B., & Hozumi, A. (2012). A Physical Approach To Specifically Improve the Mobility of Alkane Liquid Drops. Journal of the American Chemical Society. https://doi.org/10.1021/ja302903e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.