The DOI matches its Crossref record.
Conjugated Microporous Polymers as Molecular Sensing Devices: Microporous Architecture Enables Rapid Response and Enhances Sensitivity in Fluorescence-On and Fluorescence-Off Sensing
Abstract
Conjugated polymers are attractive materials for the detection of chemicals because of their remarkable π-conjugation and photoluminescence properties. In this article, we report a new strategy for the construction of molecular detection systems with conjugated microporous polymers (CMPs). The condensation of a carbazole derivative, TCB, leads to the synthesis of a conjugated microporous polymer (TCB-CMP) that exhibits blue luminescence and possesses a large surface area. Compared with a linear polymer analogue, TCB-CMP showed enhanced detection sensitivity and allowed for the rapid detection of arenes upon exposure to their vapors. TCB-CMP displayed prominent fluorescence enhancement in the presence of electron-rich arene vapors and drastic fluorescence quenching in the presence of electron-deficient arene vapors, and it could be reused without a loss of sensitivity and responsiveness. These characteristics are attributed to the microporous conjugated network of the material. Specifically, the micropores absorb arene molecules into the confined space of the polymer, the skeleton possesses a large surface area and provides a broad interface for arenes, and the network architecture facilitates exciton migration over the framework. These structural features function cooperatively, enhancing the signaling activity of TCB-CMP in fluorescence-on and fluorescence-off detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Porous Organic Materials: Strategic Design and Structure–Function Correlation
Das, S., Heasman, P., Ben, T., & Qiu, S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00439 · Cited by 1,286
Fluorescence based explosive detection: from mechanisms to sensory materials
Sun, X., Wang, Y., & Lei, Y. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00496a · Cited by 1,243
Porous organic polymers as a platform for sensing applications
Wang, S., Li, H., Huang, H., Cao, X., Chen, X., & Cao, D. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00059h · Cited by 363
Gu, C., Huang, N., Gao, J., Xu, F., Xu, Y., & Jiang, D. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201402141 · Cited by 295
Self-citationDing, X., & Han, B. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201501732 · Cited by 269
Metadata
- Authors
- Liu, X., Xu, Y., & Jiang, D.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-05-18
- Volume
- 134
- Issue
- 21
- Pages
- 8738-8741
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2324964879
- Cited by
- 495
- References
- 0
- FWCI
- 18.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Conjugated Microporous Polymers as Molecular Sensing Devices: Microporous Architecture Enables Rapid Response and Enhances Sensitivity in Fluorescence-On and Fluorescence-Off Sensing. https://app.cochat.ai/papers/10.1021/ja303448r
- The paper
- Liu, X., Xu, Y., & Jiang, D. (2012). Conjugated Microporous Polymers as Molecular Sensing Devices: Microporous Architecture Enables Rapid Response and Enhances Sensitivity in Fluorescence-On and Fluorescence-Off Sensing. Journal of the American Chemical Society. https://doi.org/10.1021/ja303448r
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.