The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Organelle-Specific Detection of Phosphatase Activities with Two-Photon Fluorogenic Probes in Cells and Tissues
Abstract
Two-photon fluorescence microscopy (TPFM) provides key advantages over conventional fluorescence imaging techniques, namely, increased penetration depth, lower tissue autofluorescence and self-absorption, and reduced photodamage and photobleaching and therefore is particularly useful for imaging deep tissues and animals. Enzyme-detecting, small molecule probes provide powerful alternatives over conventional fluorescent protein (FP)-based methods in bioimaging, primarily due to their favorable photophysical properties, cell permeability, and chemical tractability. In this article, we report the first fluorogenic, small molecule reporter system (Y2/Y1) capable of imaging endogenous phosphatase activities in both live mammalian cells and Drosophila brains. The one- and two-photon excited photophysical properties of the system were thoroughly investigated, thus confirming the system was indeed a suitable Turn-ON fluorescence pair for TPFM. To our knowledge, this is the first enzyme reporting two-photon fluorescence bioimaging system which was designed exclusively from a centrosymmetric dye possessing desirable two-photon properties. By conjugation of our reporter system to different cell-penetrating peptides (CPPs), we were able to achieve organelle- and tumor cell-specific imaging of phosphatase activities with good spatial and temporal resolution. The diffusion problem typically associated with most small molecule imaging probes was effectively abrogated. We further demonstrated this novel two-photon system could be used for imaging endogenous phosphatase activities in Drosophila brains with a detection depth of >100 μm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serine/threonine phosphatases: mechanism through structure
Shi, Y. (2009) · Cell · doi:10.1016/j.cell.2009.10.006 · Cited by 1,488
Cited by
Small-Molecule Two-Photon Probes for Bioimaging Applications
Kim, H. M., & Cho, B. R. (2015) · Chemical Reviews · doi:10.1021/cr5004425 · Cited by 1,047
Recent progresses in small-molecule enzymatic fluorescent probes for cancer imaging
Liu, H.-W., Chen, L., Xu, C., Li, Z., Zhang, H., Zhang, X.-B., & Tan, W. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00862g · Cited by 948
Acid-Active Cell-Penetrating Peptides for in Vivo Tumor-Targeted Drug Delivery
Jin, E., Zhang, B., Sun, X., Zhou, Z., Ma, X., Sun, Q., Tang, J., Shen, Y., Van Kirk, E., Murdoch, W. J., et al. (2013) · Journal of the American Chemical Society · doi:10.1021/ja311180x · Cited by 329
Highly Selective Off–On Fluorescent Probe for Imaging Thioredoxin Reductase in Living Cells
Zhang, L., Duan, D., Liu, Y., Ge, C., Cui, X., Sun, J., & Fang, J. (2014) · Journal of the American Chemical Society · doi:10.1021/ja408792k · Cited by 254
Metadata
- Authors
- Li, L., Ge, J., Wu, H., Xu, Q.-H., & Yao, S. Q.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-07-10
- Volume
- 134
- Issue
- 29
- Pages
- 12157-12167
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2328781931
- Cited by
- 172
- References
- 1
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.