The DOI matches its Crossref record.
A New Algorithm for Reliable and General NMR Resonance Assignment
Abstract
The new FLYA automated resonance assignment algorithm determines NMR chemical shift assignments on the basis of peak lists from any combination of multidimensional through-bond or through-space NMR experiments for proteins. Backbone and side-chain assignments can be determined. All experimental data are used simultaneously, thereby exploiting optimally the redundancy present in the input peak lists and circumventing potential pitfalls of assignment strategies in which results obtained in a given step remain fixed input data for subsequent steps. Instead of prescribing a specific assignment strategy, the FLYA resonance assignment algorithm requires only experimental peak lists and the primary structure of the protein, from which the peaks expected in a given spectrum can be generated by applying a set of rules, defined in a straightforward way by specifying through-bond or through-space magnetization transfer pathways. The algorithm determines the resonance assignment by finding an optimal mapping between the set of expected peaks that are assigned by definition but have unknown positions and the set of measured peaks in the input peak lists that are initially unassigned but have a known position in the spectrum. Using peak lists obtained by purely automated peak picking from the experimental spectra of three proteins, FLYA assigned correctly 96-99% of the backbone and 90-91% of all resonances that could be assigned manually. Systematic studies quantified the impact of various factors on the assignment accuracy, namely the extent of missing real peaks and the amount of additional artifact peaks in the input peak lists, as well as the accuracy of the peak positions. Comparing the resonance assignments from FLYA with those obtained from two other existing algorithms showed that using identical experimental input data these other algorithms yielded significantly (40-142%) more erroneous assignments than FLYA. The FLYA resonance assignment algorithm thus has the reliability and flexibility to replace most manual and semi-automatic assignment procedures for NMR studies of proteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reif, B., Ashbrook, S. E., Emsley, L., & Hong, M. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-020-00002-1 · Cited by 546
Combined automated NOE assignment and structure calculation with CYANA
Güntert, P., & Buchner, L. (2015) · Journal of Biomolecular NMR · doi:10.1007/s10858-015-9924-9 · Cited by 402
Self-citationFirst-in-class MKK4 inhibitors enhance liver regeneration and prevent liver failure
Zwirner, S., Abu Rmilah, A. A., Klotz, S., Pfaffenroth, B., Kloevekorn, P., Moschopoulou, A. A., Schuette, S., Haag, M., Selig, R., Li, K., et al. (2024) · Cell · doi:10.1016/j.cell.2024.02.023 · Cited by 65
“In an iterative process, FLYA resonance assignment software (part of the software package CYANA, 57,58 in combination with manual inspection and information from the MILV-mutant spectra, was used to obtain assignments for almost all methyl groups involved in intermolecular NOEs.”
Automatic structure-based NMR methyl resonance assignment in large proteins
Pritišanac, I., Würz, J. M., Alderson, T. R., & Güntert, P. (2019) · Nature Communications · doi:10.1038/s41467-019-12837-8 · Cited by 46
Self-citationKlukowski, P., Riek, R., & Güntert, P. (2023) · Science Advances · doi:10.1126/sciadv.adi9323 · Cited by 38
Self-citationBishop, A. C., Torres-Montalvo, G., Kotaru, S., Mimun, K., & Wand, A. J. (2023) · Nature Communications · doi:10.1038/s41467-023-37219-z · Cited by 16
Metadata
- Authors
- Schmidt, E., & Güntert, P.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-07-23
- Volume
- 134
- Issue
- 30
- Pages
- 12817-12829
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2316378209
- Cited by
- 202
- References
- 0
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.