Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 221

The DOI matches its Crossref record.

Tuning the Adsorption Properties of Isoreticular Pyrazolate-Based Metal–Organic Frameworks through Ligand Modification

Open access
Colombo, Valentina, Montoro, Carmen, Maspero, Angelo, Palmisano, Giovanni, Masciocchi, Norberto, Galli, Simona, Barea, Elisa, Navarro, Jorge A. R.·2012·Journal of the American Chemical Society

Abstract

Two isoreticular series of pyrazolate-based 3D open metal-organic frameworks, MBDP_X, adopting the NiBDP and ZnBDP structure types [H(2)BDP = 1,4-bis(1H-pyrazol-4-yl)benzene], were synthesized with the new tagged organic linkers H(2)BDP_X (X = -NO(2), -NH(2), -OH). All of the MBDP_X materials have been characterized through a combination of techniques. IR spectroscopy proved the effective presence of tags, while X-ray powder diffraction (XRPD) witnessed their isoreticular nature. Simultaneous TG/DSC analyses (STA) demonstrated their remarkable thermal stability, while variable-temperature XRPD experiments highlighted their high degree of flexibility related to guest-induced fit processes of the solvent molecules included in the channels. A structural isomer of the parent NiBDP was obtained with a sulfonate tagged ligand, H(2)BDP_SO(3)H. Structure solution from powder diffraction data collected at three different temperatures (room temperature, 90, and 250 °C) allowed the determination of its structure and the comprehension of its solvent-related flexible behavior. Finally, the potential application of the tagged MOFs in selective adsorption processes for gas separation and purification purposes was investigated by conventional single component adsorption isotherms, as well as by advanced experiments of pulse gas chromatography and breakthrough curve measurements. Noteworthy, the results show that functionalization does not improve the adsorption selectivity (partition coefficients) for the resolution of gas mixtures characterized by similar high quadrupole moments (e.g., CO(2)/C(2)H(2)); however, the resolution of gas mixtures containing molecules with highly differentiated polarities (i.e., N(2)/CO(2) or CH(4)/CO(2)) is highly improved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja305267m

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Colombo, V., Montoro, C., Maspero, A., Palmisano, G., Masciocchi, N., Galli, S., Barea, E., & Navarro, J. A. R.
Venue
Journal of the American Chemical Society
Published
2012-07-19
Volume
134
Issue
30
Pages
12830-12843
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2324194052
Cited by
221
References
0
FWCI
12.59
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.