The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Real-Time Monitoring of Cell Apoptosis and Drug Screening Using Fluorescent Light-Up Probe with Aggregation-Induced Emission Characteristics
Abstract
Real-time monitoring of cell apoptosis could provide valuable insights into early detection of therapy efficiency and evaluation of disease progression. In this work, we designed and synthesized a new live-cell-permeable, fluorescent light-up probe for real-time cell apoptosis imaging. The probe is comprised of a hydrophilic caspase-specific Asp-Glu-Val-Asp (DEVD) peptide and a hydrophobic tetraphenylethene (TPE) unit, a typical fluorogen with aggregation-induced emission characteristics. In aqueous solution, the probe is almost nonfluorescent but displays significant fluorescence enhancement in response to caspase-3/-7, which are activated in the apoptotic process and able to cleave the DEVD moieties. This fluorescence "turn-on" response is ascribed to aggregation of cleaved hydrophobic TPE residues, which restricts the intramolecular rotations of TPE phenyl rings and populates the radiative decay channels. The light-up nature of the probe allows real-time monitoring of caspase-3/-7 activities both in solutions and in living cells with a high signal-to-noise ratio. The probe provides a new opportunity to screen enzyme inhibitors and evaluate the apoptosis-associated drug efficacy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aggregation-induced emission of 1-methyl-1,2,3,4,5-pentaphenylsilole
Luo, J., Xie, Z., Lam, J. W. Y., Cheng, L., Tang, B. Z., Chen, H., Qiu, C., Kwok, H. S., Zhan, X., Liu, Y., et al. (2001) · Chemical Communications · doi:10.1039/b105159h · Cited by 8,358
Self-citationHong, Y., Lam, J. W. Y., & Tang, B. Z. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15113d · Cited by 6,363
Self-citation
Cited by
Aggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Self-citationAggregation‐Induced Emission: The Whole Is More Brilliant than the Parts
Mei, J., Hong, Y., Lam, J. W. Y., Qin, A., Tang, Y., & Tang, B. Z. (2014) · Advanced Materials · doi:10.1002/adma.201401356 · Cited by 3,381
Self-citationRecent Strategies to Develop Innovative Photosensitizers for Enhanced Photodynamic Therapy
Pham, T. C., Nguyen, V.-N., Choi, Y., Lee, S., & Yoon, J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00381 · Cited by 1,813
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Self-citationRecent progresses in small-molecule enzymatic fluorescent probes for cancer imaging
Liu, H.-W., Chen, L., Xu, C., Li, Z., Zhang, H., Zhang, X.-B., & Tan, W. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00862g · Cited by 948
Metadata
- Authors
- Shi, H., Kwok, R. T. K., Liu, J., Xing, B., Tang, B. Z., & Liu, B.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-10-19
- Volume
- 134
- Issue
- 43
- Pages
- 17972-17981
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2156746575
- Cited by
- 590
- References
- 2
- FWCI
- 19.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-Time Monitoring of Cell Apoptosis and Drug Screening Using Fluorescent Light-Up Probe with Aggregation-Induced Emission Characteristics. https://app.cochat.ai/papers/10.1021/ja3064588
- The paper
- Shi, H., Kwok, R. T. K., Liu, J., Xing, B., Tang, B. Z., & Liu, B. (2012). Real-Time Monitoring of Cell Apoptosis and Drug Screening Using Fluorescent Light-Up Probe with Aggregation-Induced Emission Characteristics. Journal of the American Chemical Society. https://doi.org/10.1021/ja3064588
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.