The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Three-Mode Electrochemical Sensing of Ultralow MicroRNA Levels
Open accessAbstract
MicroRNAs (miRNAs) are an emerging class of biomarkers that are frequently deregulated in cancer cells and have shown great promise for cancer classification and prognosis. In this work, we developed a three-mode electrochemical sensor for detection and quantitation of ultralow levels of miRNAs in a wide dynamic range of measured concentrations. The sensor facilitates three detection modalities based on hybridization (H-SENS), p19 protein binding (P-SENS), and protein displacement (D-SENS). The combined three-mode sensor (HPD-SENS) identifies as low as 5 aM or 90 molecules of miRNA per 30 μL of sample without PCR amplification, and can be operated within the dynamic range from 10 aM to 1 μM. The HPD sensor is made on a commercially available gold nanoparticles-modified electrode and is suitable for analyzing multiple miRNAs on a single electrode. This three-mode sensor exhibits high selectivity and specificity and was used for sequential analysis of miR-32 and miR-122 on one electrode. In addition, the H-SENS can recognize miRNAs with different A/U and G/C content and distinguish between a fully matched miRNA and a miRNA comprising either a terminal or a middle single base mutation. Furthermore, the H- and P-SENS were successfully employed for direct detection and profiling of three endogenous miRNAs, including hsa-miR-21, hsa-miR-32, and hsa-miR-122 in human serum, and the sensor results were validated by qPCR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The functions of animal microRNAs
Ambros, V. (2004) · Nature · doi:10.1038/nature02871 · Cited by 10,728
Prediction of Mammalian MicroRNA Targets
Lewis, B. P., Shih, I.-H., Jones-Rhoades, M. W., Bartel, D. P., & Burge, C. B. (2003) · Cell · doi:10.1016/s0092-8674(03)01018-3 · Cited by 5,199
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Plasma MicroRNA-122 as a Biomarker for Viral-, Alcohol-, and Chemical-Related Hepatic Diseases
Zhang, Y., Jia, Y., Zheng, R., Guo, Y., Wang, Y., Guo, H., Fei, M., & Sun, S. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.147850 · Cited by 415
Cited by
Electrochemical Sensors and Biosensors Based on Nanomaterials and Nanostructures
Zhu, C., Yang, G., Li, H., Du, D., & Lin, Y. (2015) · Analytical Chemistry · doi:10.1021/ac5039863 · Cited by 1,741
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
Self-citationGold Nanoparticles for In Vitro Diagnostics
Zhou, W., Gao, X., Liu, D., & Chen, X. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00100 · Cited by 901
Ultrasensitive detection of miRNA with an antimonene-based surface plasmon resonance sensor
Xue, T., Liang, W., Li, Y., Sun, Y., Xiang, Y., Zhang, Y., Dai, Z., Duo, Y., Wu, L., Qi, K., et al. (2019) · Nature Communications · doi:10.1038/s41467-018-07947-8 · Cited by 764
Point of care testing: The impact of nanotechnology
Syedmoradi, L., Daneshpour, M., Alvandipour, M., Gomez, F. A., Hajghassem, H., & Omidfar, K. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.08.084 · Cited by 367
Metadata
- Authors
- Labib, M., Khan, N., Ghobadloo, S. M., Cheng, J., Pezacki, J. P., & Berezovski, M. V.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-02-11
- Volume
- 135
- Issue
- 8
- Pages
- 3027-3038
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1718419249
- Cited by
- 206
- References
- 4
- FWCI
- 9.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.