The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Activatable Rotor for Quantifying Lysosomal Viscosity in Living Cells
Abstract
We have developed Lyso-V, the first fluorescent probe of lysosomal viscosity. Because of its lysosome-actived fluorescence characteristics, Lyso-V has proved to be an ideal lysosomal tracer with high spatial and temporal resolution under laser confocal microscopy. More importantly, Lyso-V shows its practical applicability in real-time quantification of lysosomal viscosity changes in live cells through fluorescence lifetime imaging microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Minton, A. P. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.r100005200 · Cited by 1,474
Cited by
BODIPY-based probes for the fluorescence imaging of biomolecules in living cells
Kowada, T., Maeda, H., & Kikuchi, K. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00030k · Cited by 1,381
Fluorescent Probes for Sensing and Imaging within Specific Cellular Organelles
Zhu, H., Fan, J., Du, J., & Peng, X. (2016) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00292 · Cited by 984
The triplet excited state of Bodipy: formation, modulation and application
Zhao, J., Xu, K., Yang, W., Wang, Z., & Zhong, F. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00364d · Cited by 867
Yin, J., Huang, L., Wu, L., Li, J., James, T. D., & Lin, W. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00645b · Cited by 549
A Self-Calibrating Bipartite Viscosity Sensor for Mitochondria
Yang, Z., He, Y., Lee, J.-H., Park, N., Suh, M., Chae, W.-S., Cao, J., Peng, X., Jung, H., Kang, C., et al. (2013) · Journal of the American Chemical Society · doi:10.1021/ja403851p · Cited by 468
Metadata
- Authors
- Wang, L., Xiao, Y., Tian, W., & Deng, L.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-02-19
- Volume
- 135
- Issue
- 8
- Pages
- 2903-2906
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1988067945
- Cited by
- 464
- References
- 1
- FWCI
- 12.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.