The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Activatable Rotor for Quantifying Lysosomal Viscosity in Living Cells
Abstract
We have developed Lyso-V, the first fluorescent probe of lysosomal viscosity. Because of its lysosome-actived fluorescence characteristics, Lyso-V has proved to be an ideal lysosomal tracer with high spatial and temporal resolution under laser confocal microscopy. More importantly, Lyso-V shows its practical applicability in real-time quantification of lysosomal viscosity changes in live cells through fluorescence lifetime imaging microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,403
Minton, A. P. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.r100005200 · Cited by 1,474
Luby-Phelps, K. (1999) · International Review of Cytology · doi:10.1016/s0074-7696(08)60527-6 · Cited by 1,149
CFTR as a cAMP-Dependent Regulator of Sodium Channels
Stutts, M. J., Canessa, C. M., Olsen, J. C., Hamrick, M., Cohn, J. A., Rossier, B. C., & Boucher, R. C. (1995) · Science · doi:10.1126/science.7543698 · Cited by 1,088
Neufeld, E. F. (1991) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.60.070191.001353 · Cited by 900
Molecular Rotor Measures Viscosity of Live Cells via Fluorescence Lifetime Imaging
Kuimova, M. K., Yahioglu, G., Levitt, J. A., & Suhling, K. (2008) · Journal of the American Chemical Society · doi:10.1021/ja800570d · Cited by 815
The cell biology of lysosomal storage disorders
Futerman, A. H., & van Meer, G. (2004) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1423 · Cited by 796
Gonzalez-Noriega, A., Grubb, J. H., Talkad, V, & Sly, W. S. (1980) · The Journal of cell biology · doi:10.1083/jcb.85.3.839 · Cited by 736
Imaging intracellular viscosity of a single cell during photoinduced cell death
Kuimova, M. K., Botchway, S. W., Parker, A. W., Balaz, M., Collins, H. A., Anderson, H. L., Suhling, K., & Ogilby, P. R. (2009) · Nature Chemistry · doi:10.1038/nchem.120 · Cited by 639
Cited by
BODIPY-based probes for the fluorescence imaging of biomolecules in living cells
Kowada, T., Maeda, H., & Kikuchi, K. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00030k · Cited by 1,381
Fluorescent Probes for Sensing and Imaging within Specific Cellular Organelles
Zhu, H., Fan, J., Du, J., & Peng, X. (2016) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00292 · Cited by 984
Macro-/micro-environment-sensitive chemosensing and biological imaging
Yang, Z., Cao, J., He, Y., Yang, J. H., Kim, T., Peng, X., & Kim, J. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00051j · Cited by 875
The triplet excited state of Bodipy: formation, modulation and application
Zhao, J., Xu, K., Yang, W., Wang, Z., & Zhong, F. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00364d · Cited by 867
Discerning the Chemistry in Individual Organelles with Small‐Molecule Fluorescent Probes
Xu, W., Zeng, Z., Jiang, J., Chang, Y., & Yuan, L. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201510721 · Cited by 808
Yin, J., Huang, L., Wu, L., Li, J., James, T. D., & Lin, W. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00645b · Cited by 549
A Self-Calibrating Bipartite Viscosity Sensor for Mitochondria
Yang, Z., He, Y., Lee, J.-H., Park, N., Suh, M., Chae, W.-S., Cao, J., Peng, X., Jung, H., Kang, C., et al. (2013) · Journal of the American Chemical Society · doi:10.1021/ja403851p · Cited by 468
Wan, Q., Chen, S., Shi, W., Li, L., & Ma, H. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201405742 · Cited by 420
Qian, H., Cousins, M. E., Horak, E. H., Wakefield, A., Liptak, M. D., & Aprahamian, I. (2017) · Nature Chemistry · doi:10.1038/nchem.2612 · Cited by 408
Design and Application of Fluorescent Probes to Detect Cellular Physical Microenvironments
Ma, J., Sun, R., Xia, K., Xia, Q., Liu, Y., & Zhang, X. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00573 · Cited by 408
Recent advances in multifunctional fluorescent probes for viscosity and analytes
Yang, X., Zhang, D., Ye, Y., & Zhao, Y. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214336 · Cited by 340
Li, H., Shi, W., Li, X., Hu, Y., Fang, Y., & Ma, H. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b09722 · Cited by 333
A molecular rotor for measuring viscosity in plasma membranes of live cells
López-Duarte, I., Vu, T. T., Izquierdo, M. A., Bull, J. A., & Kuimova, M. K. (2014) · Chem. Commun. · doi:10.1039/c3cc47530a · Cited by 274
Fluorescent Molecular Rotors for Viscosity Sensors
Lee, S., Heo, J., Woo, H. C., Lee, J., Seo, Y. H., Lee, C., Kim, S., & Kwon, O. (2018) · Chemistry – A European Journal · doi:10.1002/chem.201801389 · Cited by 271
Jiang, N., Fan, J., Xu, F., Peng, X., Mu, H., Wang, J., & Xiong, X. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201410645 · Cited by 258
Activatable Molecular Probes With Clinical Promise for NIR‐II Fluorescent Imaging
Chen, Z., Zhou, Y., Li, L., Ma, W., Li, Y., & Yang, Z. (2025) · Small · doi:10.1002/smll.202411787 · Cited by 26
Metadata
- Authors
- Wang, L., Xiao, Y., Tian, W., & Deng, L.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-02-19
- Volume
- 135
- Issue
- 8
- Pages
- 2903-2906
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1988067945
- Cited by
- 464
- References
- 29
- FWCI
- 12.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.