The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Imprinting of Molecular Recognition Sites through Electropolymerization of Functionalized Au Nanoparticles: Development of an Electrochemical TNT Sensor Based on π-Donor−Acceptor Interactions
Abstract
Electrochemical sensors for the analysis of TNT with enhanced sensitivities are described. The enhanced sensitivities are achieved by tailoring pi-donor-acceptor interactions between TNT and pi-donor-modified electrodes or pi-donor-cross-linked Au nanoparticles linked to the electrode. In one configuration a p-aminothiophenolate monolayer-modified electrode leads to the analysis of TNT with a sensitivity corresponding to 17 ppb (74 nM). In the second configuration, the cross-linking of Au NPs by oligothioaniline bridges to the electrode yields a functionalized electrode that detects TNT with a sensitivity that corresponds to 460 ppt (2 nM). Most impressively, the imprinting of molecular TNT recognition sites into the pi-donor oligoaniline-cross-linked Au nanoparticles yields a functionalized electrode with a sensitivity that corresponds to 46 ppt (200 pM). The electrode reveals high selectivity, reusability, and stability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Daniel, M.-C., & Astruc, D. (2004) · Chemical Reviews · doi:10.1021/cr030698+ · Cited by 12,446
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Conjugated Polymer-Based Chemical Sensors
McQuade, D. T., Pullen, A. E., & Swager, T. M. (2000) · Chemical Reviews · doi:10.1021/cr9801014 · Cited by 3,718
Wulff, G. (1995) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199518121 · Cited by 2,373
Molecularly Imprinted Polymers and Their Use in Biomimetic Sensors
Haupt, K., & Mosbach, K. (2000) · Chemical Reviews · doi:10.1021/cr990099w · Cited by 2,286
Storhoff, J. J., Elghanian, R., Mucic, R. C., Mirkin, C. A., & Letsinger, R. L. (1998) · Journal of the American Chemical Society · doi:10.1021/ja972332i · Cited by 2,271
Enzyme-like Catalysis by Molecularly Imprinted Polymers
Wulff, G. (2002) · Chemical Reviews · doi:10.1021/cr980039a · Cited by 1,455
Chen, J., Law, C. C. W., Lam, J. W. Y., Dong, Y., Lo, S. M. F., Williams, I. D., Zhu, D., & Tang, B. Z. (2003) · Chemistry of Materials · doi:10.1021/cm021715z · Cited by 1,190
Fluorescent Porous Polymer Films as TNT Chemosensors: Electronic and Structural Effects
Yang, J.-S., & Swager, T. M. (1998) · Journal of the American Chemical Society · doi:10.1021/ja982293q · Cited by 1,188
The Molecular Wire Approach to Sensory Signal Amplification
Swager, T. M. (1998) · Accounts of Chemical Research · doi:10.1021/ar9600502 · Cited by 1,139
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Dasary, S. S. R., Singh, A. K., Senapati, D., Yu, H., & Ray, P. C. (2009) · Journal of the American Chemical Society · doi:10.1021/ja905134d · Cited by 722
Highly Selective and Sensitive Fluorescent Paper Sensor for Nitroaromatic Explosive Detection
Ma, Y., Li, H., Peng, S., & Wang, L. (2012) · Analytical Chemistry · doi:10.1021/ac302138c · Cited by 283
Metadata
- Authors
- Riskin, M., Tel-Vered, R., Bourenko, T., Granot, E., & Willner, I.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-07-01
- Volume
- 130
- Issue
- 30
- Pages
- 9726-9733
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2021906850
- Cited by
- 295
- References
- 35
- FWCI
- 21.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.