Solution-Gated Epitaxial Graphene as pH Sensor

Ang, Priscilla Kailian, Chen, Wei, Wee, Andrew Thye Shen, Loh, Kian Ping·2008·Journal of the American Chemical Society

Abstract

A solution-gate field effect transistor (SGFET) has been fabricated on few-layer graphene (FLG). The ideally polarizable graphene/aqueous electrolyte interface allows the capacitive charging of the surface by hydroxyl (OH-) and hydroxonium ions (H3O+). The conductivity versus gate potential curve exhibits "V" shaped ambipolar transfer characteristics of graphene, with hole and electron mobilities of 3600 cm2/Vs and 2100 cm2/Vs, respectively. The shift of the negative gate potential with pH shows a supra-Nernstian response of 99 meV/pH. Our work points to the potential application of graphene in ultrafast and ultralow noise chemical or biological sensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja805090z

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 723

Metadata

Authors
Ang, P. K., Chen, W., Wee, A. T. S., & Loh, K. P.
Venue
Journal of the American Chemical Society
Published
2008-10-14
Volume
130
Issue
44
Pages
14392-14393
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2023711677
Cited by
723
References
2
FWCI
31.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Solution-Gated Epitaxial Graphene as pH Sensor. https://app.cochat.ai/papers/10.1021/ja805090z
The paper
Ang, P. K., Chen, W., Wee, A. T. S., & Loh, K. P. (2008). Solution-Gated Epitaxial Graphene as pH Sensor. Journal of the American Chemical Society. https://doi.org/10.1021/ja805090z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.