Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 167

The DOI matches its Crossref record.

Ru(bpy)3 Covalently Doped Silica Nanoparticles as Multicenter Tunable Structures for Electrochemiluminescence Amplification

Zanarini, Simone, Rampazzo, Enrico, Ciana, Leopoldo Della, Marcaccio, Massimo, Marzocchi, Ettore, Montalti, Marco, Paolucci, Francesco, Prodi, Luca·2009·Journal of the American Chemical Society

Abstract

The electrochemiluminescence (ECL) of doped silica nanoparticles (DSNPs), prepared by a reverse microemulsion method that leads to covalent incorporation of the Ru(bpy)(3)(2+), was investigated in acetonitrile and aqueous buffers. The emission was produced for the first time by cation-anion direct annihilation, and the position of ECL maxima indirectly allowed estimation of the E(1/2,IOx) and E(1/2,IRed) potentials for Ru(bpy)(3) inside DSNPs. The weak ECL emission is most likely generated by an intrananoparticle ruthenium unit annihilation rather than by the electron transfer between a reduced and oxidized DSNP due to the very low diffusivities of the nanoparticles. Thiol-terminated DSNPs were self-assembled on gold substrates, forming compact and stable monolayers which mimic probe-target assays with DSNPs as labels. The ECL intensity obtained by such functionalized substrates in aqueous media, using tripropylamine (TPrA) as coreactant, was surprisingly increased with respect to direct electrochemical oxidation because of the ability of oxidized TPrA to diffuse within the DSNPs structure and reach a higher number of emitting units with respect to direct electron tunneling. The experimental results have been explained by proposing a basic physical-chemical model which supports evaluation of the number of redox-active centers per nanoparticle. In the model the contrasting effects of increased luminescence quantum yield and decreased diffusion coefficient with respect to free (i.e., not bound within the silica structure) emitting molecules were taken into account. This allows, in principle, optimizing the ECL emission intensity as a function of DSNP size, doping material, charge, doping level, supporting electrolyte, electrode material, and solvent. Finally, it is worth noting that this study has provided a more than 1000-fold increase of the ECL signal of a chemically and electrochemically stable DSNP compared to that of a single dye, suggesting that use of this kind of nanostructures as luminescent labels represents a very promising system for ultrasensitive bioanalysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja8077158

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Zanarini, S., Rampazzo, E., Ciana, L. D., Marcaccio, M., Marzocchi, E., Montalti, M., Paolucci, F., & Prodi, L.
Venue
Journal of the American Chemical Society
Published
2009-01-22
Volume
131
Issue
6
Pages
2260-2267
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2093585617
Cited by
167
References
0
FWCI
6.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.