Structural and Dynamic Parameters Obtained from 17O NMR, EPR, and NMRD Studies of Monomeric and Dimeric Gd3+ Complexes of Interest in Magnetic Resonance Imaging: An Integrated and Theoretically Self-Consistent Approach1
Open accessAbstract
We present the results of new and previously published 17 O NMR, EPR, and NMRD studies of aqueous solutions of the Gd 3+ octaaqua ion and the commercial MRI contrast agents [Gd(DTPA)(H 2 O)] 2 - (MAGNEVIST, Schering AG, DTPA = 1,1,4,7,7-pentakis(carboxymethyl)-1,4,7-triazaheptane), [Gd(DTPA-BMA)(H 2 O)] (OMNISCAN, Sanofi Nycomed, DTPA-BMA = 1,7-bis[( N -methylcarbamoyl)methyl]-1,4,7-tris(carboxymethyl)-1,4,7-triazaheptane), and [Gd(DOTA)(H 2 O)] - (DOTAREM, Guerbet, DOTA = 1,4,7,10-tetrakis(carboxymethyl)-1,4,7,10-tetraazacyclododecane). High-field EPR measurements at different concentrations give evidence of an intermolecular dipole−dipole electronic relaxation mechanism that has not previously been described for Gd 3+ complexes. For the first time, the experimental data from the three techniques for each complex have been treated using a self-consistent theoretical model in a simultaneous multiple parameter least-squares fitting procedure. The lower quality of the fits compared to separate fits of the data for each of the three techniques shows that the increase in the number of adjustable parameters is outweighed by the increased constraint on the fits. The parameters governing the relaxivity of the complexes are thus determined with greater confidence than previously possible. The same approach was used to study two dimeric Gd 3+ complexes [pip{Gd(DO3A)(H 2 O)} 2 ] and [bisoxa{Gd(DO3A)(H 2 O)} 2 ] (pip(DO3A) 2 = bis(1,4-(1-(carboxymethyl)-1,4,7,10-tetraaza-4,7,10-tris(carboxymethyl)-1-cyclododecyl-1,4-diazacyclohexane, bisoxa(DO3A) 2 = bis(1,4-(1-(carboxymethyl)-1,4,7,10-tetraaza-4,7,10-tris(carboxymethyl)-1-cyclododecyl))-1,10-diaza-3,6-dioxadecane) that are being developed as potential second-generation MRI contrast agents. These dimeric complexes are expected to have higher relaxivities than the monomeric contrast agents, due to their longer rotational correlation times. The results of this study show that further relaxivity gain for these complexes will be hindered by the slow rate of water exchange on the complexes. High-field EPR measurements suggest that there is a previously unrecorded intramolecular dipole−dipole mechanism of electronic relaxation, but that this additional contribution to electronic relaxation is of minor importance compared to the limiting effect of water exchange rates in the determination of proton relaxivity in MRI applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modified Spin-Echo Method for Measuring Nuclear Relaxation Times
Meiboom, S., & Gill, D. (1958) · Review of Scientific Instruments · doi:10.1063/1.1716296 · Cited by 6,022
Relaxation Processes in a System of Two Spins
Solomon, I. (1955) · Physical Review · doi:10.1103/physrev.99.559 · Cited by 3,278
Paramagnetic metal complexes as water proton relaxation agents for NMR imaging: theory and design
Lauffer, R. B. (1987) · Chemical Reviews · doi:10.1021/cr00081a003 · Cited by 1,978
Self-diffusion in normal and heavy water in the range 1-45.deg.
Mills, R. (1973) · The Journal of Physical Chemistry · doi:10.1021/j100624a025 · Cited by 1,706
Swift, T. J., & Connick, R. E. (1962) · The Journal of Chemical Physics · doi:10.1063/1.1701321 · Cited by 1,292
Proton Relaxation Times in Paramagnetic Solutions
Bloembergen, N. (1957) · The Journal of Chemical Physics · doi:10.1063/1.1743771 · Cited by 1,056
Interpretation of magnetic resonance data from water nuclei in heterogeneous systems
Halle, B., & Wennerström, H. (1981) · The Journal of Chemical Physics · doi:10.1063/1.442218 · Cited by 490
A simple multinuclear NMR thermometer
Ammann, C., Meier, P., & Merbach, A. (1982) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(82)90147-0 · Cited by 451
Self-citationFreed, J. H. (1978) · The Journal of Chemical Physics · doi:10.1063/1.436302 · Cited by 442
Field-cycling relaxometry of protein solutions and tissue: Implications for MRI
Koenig, S. H., & Brown, R. D. (1990) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/0079-6565(90)80008-6 · Cited by 363
Cited by
Gadolinium(III) Chelates as MRI Contrast Agents: Structure, Dynamics, and Applications
Caravan, P., Ellison, J. J., McMurry, T. J., & Lauffer, R. B. (1999) · Chemical Reviews · doi:10.1021/cr980440x · Cited by 4,483
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Strategies for increasing the sensitivity of gadolinium based MRI contrast agents
Caravan, P. (2006) · Chemical Society Reviews · doi:10.1039/b510982p · Cited by 1,438
Parker, D., Dickins, R. S., Puschmann, H., Crossland, C., & Howard, J. A. K. (2002) · Chemical Reviews · doi:10.1021/cr010452+ · Cited by 834
Inorganic and Bioinorganic Solvent Exchange Mechanisms
Helm, L., & Merbach, A. E. (2005) · Chemical Reviews · doi:10.1021/cr030726o · Cited by 792
Self-citationActivation and Reaction Volumes in Solution. 3
Drljaca, A., Hubbard, C. D., van Eldik, R., Asano, T., Basilevsky, M. V., & le Noble, W. J. (1998) · Chemical Reviews · doi:10.1021/cr970461b · Cited by 546
Gadolinium(iii) complexes as MRI contrast agents: ligand design and properties of the complexes
Hermann, P., Kotek, J., Kubíček, V., & Lukeš, I. (2008) · Dalton Transactions · doi:10.1039/b719704g · Cited by 530
High‐Relaxivity MRI Contrast Agents: Where Coordination Chemistry Meets Medical Imaging
Werner, E. J., Datta, A., Jocher, C. J., & Raymond, K. N. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200800212 · Cited by 463
Laurent, S., Elst, L. V., & Muller, R. N. (2006) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.100 · Cited by 441
Paramagnetic NMR in solution and the solid state
Pell, A. J., Pintacuda, G., & Grey, C. P. (2019) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.05.001 · Cited by 439
Chemical Exchange Saturation Transfer Contrast Agents for Magnetic Resonance Imaging
Sherry, A. D., & Woods, M. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151929 · Cited by 356
Guo, Z., & Sadler, P. J. (1999) · Advances in Inorganic Chemistry · doi:10.1016/s0898-8838(08)60271-8 · Cited by 354
Gd(III)-BASED CONTRAST AGENTS FOR MRI
AIME, S., BOTTA, M., & TERRENO, E. (2005) · Advances in Inorganic Chemistry · doi:10.1016/s0898-8838(05)57004-1 · Cited by 345
Recent advances in utilization of transition metal complexes and lanthanides as diagnostic tools
Yam, V. W.-W., & Lo, K. K.-W. (1999) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(98)00262-8 · Cited by 268
Lanthanoid Endohedral Metallofullerenols for MRI Contrast Agents
Kato, H., Kanazawa, Y., Okumura, M., Taninaka, A., Yokawa, T., & Shinohara, H. (2003) · Journal of the American Chemical Society · doi:10.1021/ja027555+ · Cited by 261
Mechanistic Studies of Metal Aqua Ions: A Semi‐Historical Perspective
Lincoln, S. F. (2005) · Helvetica Chimica Acta · doi:10.1002/hlca.200590036 · Cited by 110
Metadata
- Authors
- Powell, D. H., Dhubhghaill, O. M. N., Pubanz, D., Helm, L., Lebedev, Y. S., Schlaepfer, W., & Merbach, A. E.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-01-01
- Volume
- 118
- Issue
- 39
- Pages
- 9333-9346
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W619105361
- Cited by
- 654
- References
- 23
- FWCI
- 17.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.