The DOI matches its Crossref record.
Unimolecular Reaction Kinetics in the High-Pressure Limit without Collisions
Open accessAbstract
Molecular activation by blackbody photons, first postulated in 1919 by Perrin, plays a dominant role in the unimolecular dissociation of large ions trapped at low pressure in a Fourier-transform mass spectrometer. Under readily achievable experimental conditions, molecular ions of the protein ubiquitin equilibrate with the blackbody radiation field inside the vacuum chamber. The internal energy of a population of these ions is given by a Boltzmann distribution. From the temperature dependence of unimolecular dissociation rate constants measured in the zero-pressure limit, Arrhenius activation parameters equal to those in the high-pressure limit are obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Fragmentation pathways of protonated peptides
Paizs, B., & Suhai, S. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20024 · Cited by 1,118
Mobile and localized protons: a framework for understanding peptide dissociation
Wysocki, V. H., Tsaprailis, G., Smith, L. L., & Breci, L. A. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200012)35:12<1399::aid-jms86>3.0.co;2-r · Cited by 997
Ion activation methods for tandem mass spectrometry
Sleno, L., & Volmer, D. A. (2004) · Journal of Mass Spectrometry · doi:10.1002/jms.703 · Cited by 529
Luo, Z., Castleman, A. W., & Khanna, S. N. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00230 · Cited by 515
Protein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 408
Peptides and Proteins in the Vapor Phase
Jarrold, M. F. (2000) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.51.1.179 · Cited by 361
Influence of Secondary Structure on the Fragmentation of Protonated Peptides
Tsaprailis, G., Nair, H., Somogyi, Á., Wysocki, V. H., Zhong, W., Futrell, J. H., Summerfield, S. G., & Gaskell, S. J. (1999) · Journal of the American Chemical Society · doi:10.1021/ja982980h · Cited by 350
Milestones in fourier transform ion cyclotron resonance mass spectrometry technique development
Marshall, A. G. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00324-9 · Cited by 295
Molecular recognition and supramolecular chemistry in the gas phase
Schalley, C. A. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10009 · Cited by 284
Prediction of Low-Energy Collision-Induced Dissociation Spectra of Peptides
Zhang, Z. (2004) · Analytical Chemistry · doi:10.1021/ac049951b · Cited by 281
Rodriguez-Cruz, S. E., Jockusch, R. A., & Williams, E. R. (1999) · Journal of the American Chemical Society · doi:10.1021/ja9911871 · Cited by 201
Self-citation
Metadata
- Authors
- Price, W. D., Schnier, P. D., Jockusch, R. A., Strittmatter, E. F., & Williams, E. R.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-01-01
- Volume
- 118
- Issue
- 43
- Pages
- 10640-10644
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2025710073
- Cited by
- 189
- References
- 0
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.