The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Force Titrations and Ionization State Sensitive Imaging of Functional Groups in Aqueous Solutions by Chemical Force Microscopy
Abstract
Chemical force microscopy (CFM) was used to probe interactions between ionizable and neutral functional groups in aqueous solutions. Force microscope probe tips and sample substrates have been covalently modified with self-assembled monolayers (SAMs) terminating in distinct functional groups. SAMs were prepared by treating Au-coated or uncoated tips and substrates with functionalized thiols or silanes, respectively. A force microscope has been used to characterize adhesive and frictional interactions between probe tips and substrates modified with SAMs that terminate in −NH 2, −COOH, −OH, and −CH 3 functional groups as a function of solution pH and ionic strength. In general, adhesion and friction forces were observed to depend on the chemical identity of the tip and sample surface and also were found to be highly sensitive to the changes in the ionization state of the terminal functionalities induced by varying the solution pH. Adhesion measurements made as a function of pH (force titrations) on amine-terminated surfaces exhibit a sharp decrease in the adhesion force at pH values below 4.5. The p K a estimated from this drop in adhesion, which is due to the protonation of amine groups on the sample and tip, 3.9, is similar to the value determined by conventional contact angle wetting studies of these same surfaces. The large decrease in the p K of the amine group relative to homogeneous solution was attributed to the relatively hydrophobic environment of the amine group in these SAMs. Adhesion measurements made as a function of pH on −COOH-terminated surfaces exhibited a large drop in adhesion force for pH values greater than 5. The p K a estimated from these data, 5.5, is similar to the free aqueous solution value. In addition, the adhesion force between nonionizable −OH and −CH 3 groups was found to be independent of solution pH. The measured adhesive forces were interpreted using a contact mechanics model that incorporated the effects of the double layer free energy. Analyses of repulsive electrostatic forces and adhesion data recorded as a function of ionic strength were used to determine properties of the double layer. The pH dependence of the friction force between tips and samples modified with SAMs terminating in −COOH, −OH, and −CH 3 groups was measured as a function of applied load. For a given pH, these data exhibit a linear dependence on load with the slope corresponding to the coefficient of friction. The coefficient of friction for −OH and −CH 3 groups was independent of pH, while the friction coefficient for −COOH-terminated surfaces drops significantly at a pH corresponding to the p K a determined by adhesion measurements. The pH-dependent changes in friction forces for ionizable groups were exploited to map spatially changes in ionization state on surfaces terminating in −COOH and −OH functional groups.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Direct observation of kinesin stepping by optical trapping interferometry
Svoboda, K., Schmidt, C. F., Schnapp, B. J., & Block, S. M. (1993) · Nature · doi:10.1038/365721a0 · Cited by 1,910
Pashley, R. M. (1981) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(81)90348-9 · Cited by 958
Cited by
Covalently functionalized nanotubes as nanometre- sized probes in chemistry and biology
Wong, S. S., Joselevich, E., Woolley, A. T., Cheung, C. L., & Lieber, C. M. (1998) · Nature · doi:10.1038/27873 · Cited by 1,451
Self-citationHwang, S.-W., Lee, C. H., Cheng, H., Jeong, J.-W., Kang, S.-K., Kim, J.-H., Shin, J., Yang, J., Liu, Z., Ameer, G. A., et al. (2015) · Nano Letters · doi:10.1021/nl503997m · Cited by 344
Structural and functional imaging with carbon nanotube AFM probes
Hafner, J. H., Cheung, C.-L., Woolley, A. T., & Lieber, C. M. (2001) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(01)00011-6 · Cited by 344
Self-citationAdhesive and Friction Forces between Chemically Modified Silicon and Silicon Nitride Surfaces
Tsukruk, V. V., & Bliznyuk, V. N. (1998) · Langmuir · doi:10.1021/la970367q · Cited by 318
Geiger, F. M. (2009) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.59.032607.093651 · Cited by 289
Chemical and Biochemical Analysis Using Scanning Force Microscopy
Takano, H., Kenseth, J. R., Wong, S.-S., O'Brie, J. C., & Porter, M. D. (1999) · Chemical Reviews · doi:10.1021/cr9801317 · Cited by 259
The mechanics of nanometre-scale molecular contacts
Busuttil, K., Nikogeorgos, N., Zhang, Z., Geoghegan, M., Hunter, C. A., & Leggett, G. J. (2012) · Faraday Discussions · doi:10.1039/c2fd00133k · Cited by 16
Metadata
- Authors
- Vezenov, D. V., Noy, A., Rozsnyai, L. F., & Lieber, C. M.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-02-01
- Volume
- 119
- Issue
- 8
- Pages
- 2006-2015
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1989940830
- Cited by
- 438
- References
- 2
- FWCI
- 18.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.