Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 201

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Metal−Insulator Transitions, Structural and Microstructural Evolution of RNiO3 (R = Sm, Eu, Gd, Dy, Ho, Y) Perovskites: Evidence for Room-Temperature Charge Disproportionation in Monoclinic HoNiO3 and YNiO3

Alonso, José A., Martínez-Lope, María J., Casais, María T., Aranda, Miguel A. G., Fernández-Díaz, María T.·1999·Journal of the American Chemical Society

Abstract

RNiO 3 nickelates have been prepared under high oxygen pressure (R = Sm, Eu, Gd) or high hydrostatic pressure (R = Dy, Ho, Y) in the presence of KClO 4 . The samples have been investigated at room temperature (RT) by synchrotron X-ray powder diffraction to follow the evolution of the crystal structures and microstructures along the series. The distortion of the orthorhombic (space group Pbnm ) perovskite progressively increases along the series, leading for the smallest Ho 3+ and Y 3+ cations to a subtle monoclinic distortion (space group P 2 1 / n ) which implies the splitting of the Ni positions in the crystal. This symmetry was confirmed by neutron powder diffraction; the crystal structures for R Ho and Y were refined simultaneously from RT synchrotron and neutron powder diffraction data. In both perovskites the oxygen octahedra around Ni1 and Ni2 positions are significantly distorted, suggesting the manifestation of Jahn−Teller effect, which is almost absent in the nickelates of lighter rare earths. The very distinct mean Ni−O bond distances observed for Ni1 and Ni2 atoms at RT, in the insulating regime, suggest the presence of a charge disproportionation effect, considered as driving force for the splitting of the Ni positions. The metal−insulator (MI) transitions for RNiO 3 (R = Gd, Dy, Ho, Y), above room temperature, have been characterized by DSC. The transition temperatures for Gd, Dy, Ho, and Y oxides in the heating runs are 510.7, 563.9, 572.7, and 581.9 K, respectively. The increasing rate of T MI for Dy, Ho, and Y materials is lower than that expected from the variation of T MI for the larger rare earth perovskites. This is probably related to the subtle monoclinic distortion found for Ho and Y nickelates. The high-resolution synchrotron X-ray powder patterns have revealed changes in the microstructure along the series. Powder patterns for orthorhombic RNiO 3 (R = Sm, Eu, Gd, Dy) display asymmetric tails for some reflections which are due to structural mistakes such as stacking faults or regular intergrowths. These mistakes are not present in monoclinic RNiO 3 (R Ho, Y) nickelates.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja984015x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Alonso, J. A., Martínez-Lope, M. J., Casais, M. T., Aranda, M. A. G., & Fernández-Díaz, M. T.
Venue
Journal of the American Chemical Society
Published
1999-05-01
Volume
121
Issue
20
Pages
4754-4762
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2129007702
Cited by
201
References
1
FWCI
6.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.