The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Well-Controlled Polymerization of Phenylacetylenes with Organorhodium(I) Complexes: Mechanism and Structure of the Polyenes
Abstract
A tetracoordinate rhodium complex, Rh(C⋮CC 6 H 5 )(nbd)[P(C 6 H 5 ) 3 ] (nbd = 2,5-norbornadiene), combined with 4-(dimethylamino)pyridine (DMAP) is an excellent initiator for the stereospecific living polymerization of phenylacetylene and its m - and p -substituted derivatives. The rhodium initiator can be generated efficiently by dissociation of triphenylphosphine from isolable Rh(C⋮CC 6 H 5 )(nbd)[P(C 6 H 5 ) 3 ] 2 or by reacting Rh(CH 3 )(nbd)[P(C 6 H 5 ) 3 ] 2 or [Rh(OCH 3 )(nbd)] 2 /P(C 6 H 5 ) 3 with one equivalent of phenylacetylene. The use of a phenylethynyl group, triphenylphosphine, and NBD ligand attached to the rhodium center is crucial for the well-controlled polymerization of phenylacetylenes. An additive, DMAP, is necessary to attain low polydispersities of the polymer products. An active rhodium(I) complex bearing a growing polymer chain, NBD, and P(C 6 H 5 ) 3 was isolated from a reaction mixture and was characterized by NMR, GC−MS, XPS, and elemental analyses. The isolated active polymer initiates the further polymerization of the same monomer or substituted ones with an almost 100% initiation efficiency to give higher molecular weight homopolymers or block copolymers, respectively. Detailed NMR structural analysis of the products indicated that the polymerization with the rhodium(I) complexes proceeds via a 2,1-insertion mechanism to provide stereoregular poly(phenylacetylene)s with cis−transoidal backbone structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Crystallographic Computing 6: A Window on Modern Crystallography
(1993) · doi:10.1093/oso/9780198557883.001.0001 · Cited by 1,998
Kishimoto, Y., Eckerle, P., Miyatake, T., Ikariya, T., & Noyori, R. (1994) · Journal of the American Chemical Society · doi:10.1021/ja00105a095 · Cited by 230
Self-citationKishimoto, Y., Itou, M., Miyatake, T., Ikariya, T., & Noyori, R. (1995) · Macromolecules · doi:10.1021/ma00123a037 · Cited by 177
Self-citation
Cited by
Yashima, E., Ousaka, N., Taura, D., Shimomura, K., Ikai, T., & Maeda, K. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00354 · Cited by 2,004
Acetylenic Polymers: Syntheses, Structures, and Functions
Liu, J., Lam, J. W. Y., & Tang, B. Z. (2009) · Chemical Reviews · doi:10.1021/cr900149d · Cited by 1,196
Optically Active Polymers for Chiral Separation
Yamamoto, C., & Okamoto, Y. (2004) · Bulletin of the Chemical Society of Japan · doi:10.1246/bcsj.77.227 · Cited by 267
Metadata
- Authors
- Kishimoto, Y., Eckerle, P., Miyatake, T., Kainosho, M., Ono, A., Ikariya, T., & Noyori, R.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-12-01
- Volume
- 121
- Issue
- 51
- Pages
- 12035-12044
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2042029879
- Cited by
- 268
- References
- 3
- FWCI
- 9.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.