Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 298

The DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.

Targeted Solvatochromic Fluorescent Probes for Imaging Lipid Order in Organelles under Oxidative and Mechanical Stress

Open access
Danylchuk, Dmytro I., Jouard, Pierre-Henri, Klymchenko, Andrey S.·2021·Journal of the American Chemical Society

Abstract

Biomembranes constitute a basis for all compartments of live cells, and therefore, the monitoring of their lipid organization is essential for understanding cell status and activity. However, the sensing and imaging of lipid organization specifically in different organelles of live cells remain challenging. Here, we designed an array of solvatochromic probes based on Nile Red bearing ligands for specific targeting of the endoplasmic reticulum, mitochondria, lysosomes, Golgi apparatus, plasma membranes, and lipid droplets. These polarity-sensitive probes detected variations in the lipid order by changing their emission maximum, as evidenced by fluorescence spectroscopy in model membranes. In colocalization microscopy experiments with reference organelle markers, they exhibited good organelle selectivity. Using two-color fluorescence microscopy, the new probes enabled imaging of the local polarity of organelles in live cells. To exclude the biased effect of the probe design on the sensitivity to the membrane properties, we calibrated all probes in model membranes under the microscope, which enabled the first quantitative description of the lipid order in each organelle of interest. Cholesterol extraction/enrichment confirmed the capacity of the probes to sense the lipid order, revealing that organelles poor in cholesterol are particularly affected by its enrichment. The probes also revealed that oxidative and mechanical stresses produced changes in the local polarity and lipid order that were characteristic for each organelle, with mitochondria and lysosomes being particularly stress sensitive. The new probes constitute a powerful toolbox for monitoring the response of the cells to physical and chemical stimuli at the level of membranes of individual organelles, which remains an underexplored direction in cellular research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jacs.0c10972

Cites

71 of 71 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 71 references

Metadata

Authors
Danylchuk, D. I., Jouard, P.-H., & Klymchenko, A. S.
Venue
Journal of the American Chemical Society
Published
2021-01-08
Volume
143
Issue
2
Pages
912-924
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W3119331823
Cited by
298
References
71
FWCI
13.48
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Targeted Solvatochromic Fluorescent Probes for Imaging Lipid Order in Organelles under Oxidative and Mechanical Stress. https://app.cochat.ai/papers/10.1021/jacs.0c10972
The paper
Danylchuk, D. I., Jouard, P.-H., & Klymchenko, A. S. (2021). Targeted Solvatochromic Fluorescent Probes for Imaging Lipid Order in Organelles under Oxidative and Mechanical Stress. Journal of the American Chemical Society. https://doi.org/10.1021/jacs.0c10972

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.