Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 166

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

General Surface-Enhanced Raman Spectroscopy Method for Actively Capturing Target Molecules in Small Gaps

Ge, Meihong, Li, Pan, Zhou, Guoliang, Chen, Siyu, Han, Wei, Qin, Feng, Nie, Yuman, Wang, Yaoxiong, Qin, Miao, Huang, Guangyao, Li, Shaofei, Wang, Yongtao, Yang, Liangbao, Tian, Zhongqun·2021·Journal of the American Chemical Society

Abstract

Over the past decade, many efforts have been devoted to designing and fabricating substrates for surface-enhanced Raman spectroscopy (SERS) with abundant hot spots to improve the sensitivity of detection. However, there have been many difficulties involved in causing molecules to enter hot spots actively or effectively. Here, we report a general SERS method for actively capturing target molecules in small gaps (hot spots) by constructing a nanocapillary pumping model. The ubiquity of hot spots and the inevitability of molecules entering them lights up all the hot spots and makes them effective. This general method can realize the highly sensitive detection of different types of molecules, including organic pollutants, drugs, poisons, toxins, pesticide residues, dyes, antibiotics, amino acids, antitumor drugs, explosives, and plasticizers. Additionally, in the dynamic detection process, an efficient and stable signal can be maintained for 1-2 min, which increases the practicality and operability of this method. Moreover, a dynamic detection process like this corresponds to the processes of material transformation in some organisms, so the method can be used to monitor transformation processes such as the death of a single cell caused by photothermal stimulation. Our method provides a novel pathway for generating hot spots that actively attract target molecules, and it can achieve general ultratrace detection of diverse substances and be applied to the study of cell behaviors in biological systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jacs.1c02169

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 166

Metadata

Authors
Ge, M., Li, P., Zhou, G., Chen, S., Han, W., Qin, F., Nie, Y., Wang, Y., Qin, M., Huang, G., Li, S., Wang, Y., Yang, L., & Tian, Z.
Venue
Journal of the American Chemical Society
Published
2021-05-14
Volume
143
Issue
20
Pages
7769-7776
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W3162592562
Cited by
166
References
1
FWCI
7.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: General Surface-Enhanced Raman Spectroscopy Method for Actively Capturing Target Molecules in Small Gaps. https://app.cochat.ai/papers/10.1021/jacs.1c02169
The paper
Ge, M., Li, P., Zhou, G., Chen, S., Han, W., Qin, F., Nie, Y., Wang, Y., Qin, M., Huang, G., Li, S., Wang, Y., Yang, L., & Tian, Z. (2021). General Surface-Enhanced Raman Spectroscopy Method for Actively Capturing Target Molecules in Small Gaps. Journal of the American Chemical Society. https://doi.org/10.1021/jacs.1c02169

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.