Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 207

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

A Sensitive and Reliable Organic Fluorescent Nanothermometer for Noninvasive Temperature Sensing

Xue, Ke, Wang, Chao, Wang, Jiaxin, Lv, Shuyi, Hao, Boyi, Zhu, Chunlei, Tang, Ben Zhong · 2021 · Journal of the American Chemical Society

Abstract

Sensing temperature at the subcellular level is of great importance for the understanding of miscellaneous biological processes. However, the development of sensitive and reliable organic fluorescent nanothermometers remains challenging. In this study, we report the fabrication of a novel organic fluorescent nanothermometer and study its application in temperature sensing. First of all, we synthesize a dual-responsive organic luminogen that can respond to the molecular state of aggregation and environmental polarity. Next, natural saturated fatty acids with sharp melting points as well as reversible and rapid phase transition are employed as the encapsulation matrix to correlate external heat information with the fluorescence properties of the luminogen. To apply the composite materials for biological application, we formulate them into colloidally dispersed nanoparticles by a technique that combines in situ surface polymerization and nanoprecipitation. As anticipated, the resultant zwitterionic nanothermometer exhibits sensitive, reversible, reliable, and multiparametric responses to temperature variation within a narrow range around the physiological temperature (i.e., 37 °C). Taking spectral position, fluorescence intensity, and fluorescence lifetime as the correlation parameters, the maximum relative thermal sensitivities are determined to be 2.15% °C –1, 17.06% °C –1, and 17.72% °C –1, respectively, which are much higher than most fluorescent nanothermometers. Furthermore, we achieve the multimodal temperature sensing of bacterial biofilms using these three complementary fluorescence parameters. Besides, we also fabricate a cationic form of the nanothermometer to facilitate efficient cellular uptake, holding great promise for studying thermal behaviors in biological systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jacs.1c04597

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 207

Metadata

Authors
Xue, K., Wang, C., Wang, J., Lv, S., Hao, B., Zhu, C., & Tang, B. Z.
Venue
Journal of the American Chemical Society
Published
2021-07-21
Volume
143
Issue
35
Pages
14147-14157
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W3183386028
Cited by
207
References
5
FWCI
8.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Sensitive and Reliable Organic Fluorescent Nanothermometer for Noninvasive Temperature Sensing. https://app.cochat.ai/papers/10.1021/jacs.1c04597
The paper
Xue, K., Wang, C., Wang, J., Lv, S., Hao, B., Zhu, C., & Tang, B. Z. (2021). A Sensitive and Reliable Organic Fluorescent Nanothermometer for Noninvasive Temperature Sensing. Journal of the American Chemical Society. https://doi.org/10.1021/jacs.1c04597

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.