The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An Activatable Near-Infrared Fluorescence Probe for in Vivo Imaging of Acute Kidney Injury by Targeting Phosphatidylserine and Caspase-3
Abstract
Renal-clearable and target-responsive near-infrared (NIR) fluorescent imaging probes have been promising for in vivo diagnosis of acute kidney injury (AKI). However, designing an imaging probe that is renal-clearable and concurrently responsive toward multiple molecular targets to facilitate early detection of AKI with improved sensitivity and specificity is challenging. Herein, by leveraging the receptor-mediated binding and retention effect along with enzyme-triggered fluorescence activation, we design and synthesize an activatable small-molecule NIR fluorescent probe ( 1-DPA 2 ) using a “one-pot sequential click reaction” approach. 1-DPA 2 can target both the externalized phosphatidylserine (PS) and active caspase-3 (Casp-3), two essential biomarkers of apoptosis, producing enhanced 808 nm NIR fluorescence and a high signal-to-background ratio (SBR) amenable to detecting the onset of cisplatin-induced AKI in mice as early as 24 h post-treatment with cisplatin. We not only monitor the gradual activation of Casp-3 in the kidney of mice upon AKI progression but also can report on the progressive recovery of kidney functions in AKI mice following N -acetyl- l -cysteine (NAC) therapy via real-time fluorescence imaging by 1-DPA 2 . This study demonstrates the ability of 1-DPA 2 for longitudinal monitoring of renal cell apoptosis by concurrently targeting PS externalization and Casp-3 activation, which is efficient for early diagnosis of AKI and useful for prediction of potential drug nephrotoxicity as well as in vivo screening of anti-AKI drugs’ efficacy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, J., Xie, C., Zhang, X., Jiang, Y., Li, J., Fan, Q., & Pu, K. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201909560 · Cited by 258
Cited by
Zeng, S., Liu, X., Kafuti, Y. S., Kim, H., Wang, J., Peng, X., Li, H., & Yoon, J. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00799a · Cited by 341
Explainable Deep-Learning-Assisted Sweat Assessment via a Programmable Colorimetric Chip
Liu, Z., Li, J., Li, J., Yang, T., Zhang, Z., Wu, H., Xu, H., Meng, J., & Li, F. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c03927 · Cited by 59
Kamya, E., Lu, Z., Cao, Y., & Pei, R. (2022) · Journal of Materials Chemistry B · doi:10.1039/d2tb01903e · Cited by 10
Metadata
- Authors
- Weng, J., Wang, Y., Zhang, Y., & Ye, D.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-10-21
- Volume
- 143
- Issue
- 43
- Pages
- 18294-18304
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W3207701835
- Cited by
- 173
- References
- 1
- FWCI
- 9.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Activatable Near-Infrared Fluorescence Probe for in Vivo Imaging of Acute Kidney Injury by Targeting Phosphatidylserine and Caspase-3. https://app.cochat.ai/papers/10.1021/jacs.1c08898
- The paper
- Weng, J., Wang, Y., Zhang, Y., & Ye, D. (2021). An Activatable Near-Infrared Fluorescence Probe for in Vivo Imaging of Acute Kidney Injury by Targeting Phosphatidylserine and Caspase-3. Journal of the American Chemical Society. https://doi.org/10.1021/jacs.1c08898
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.