The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Precision Navigation of Hepatic Ischemia–Reperfusion Injury Guided by Lysosomal Viscosity-Activatable NIR-II Fluorescence
Open accessAbstract
Hepatic ischemia-reperfusion injury (HIRI) is responsible for postoperative liver dysfunction and liver failure. Precise and rapid navigation of HIRI lesions is critical for early warning and timely development of pretreatment plans. Available methods for assaying liver injury fail to provide the exact location of lesions in real time intraoperatively. HIRI is intimately associated with oxidative stress which impairs lysosomal degradative function, leading to significant changes in lysosomal viscosity. Therefore, lysosomal viscosity is a potential biomarker for the precise targeting of HIRI. Hence, we developed a viscosity-activatable second near-infrared window fluorescent probe (NP-V) for the detection of lysosomal viscosity in hepatocytes and mice during HIRI. A reactive oxygen species-malondialdehyde-cathepsin B signaling pathway during HIRI was established. We further conducted high signal-to-background ratio NIR-II fluorescence imaging of HIRI mice. The contour and boundary of liver lesions were delineated, and as such the precise intraoperative resection of the lesion area was implemented. This research demonstrates the potential of NP-V as a dual-functional probe for the elucidation of HIRI pathogenesis and the direct navigation of HIRI lesions in clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tjäderhane, L., Buzalaf, M. A. R., Carrilho, M., & Chaussain, C. (2015) · Caries Research · doi:10.1159/000363582 · Cited by 2,306
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
Hu, Z., Fang, C., Li, B., Zhang, Z., Cao, C., Cai, M., Su, S., Sun, X., Shi, X., Li, C., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0494-0 · Cited by 1,126
Recent progresses in small-molecule enzymatic fluorescent probes for cancer imaging
Liu, H.-W., Chen, L., Xu, C., Li, Z., Zhang, H., Zhang, X.-B., & Tan, W. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00862g · Cited by 948
Cited by
Fluorescent Probes for Disease Diagnosis
Wang, X., Ding, Q., Groleau, R. R., Wu, L., Mao, Y., Che, F., Kotova, O., Scanlan, E. M., Lewis, S. E., Li, P., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00776 · Cited by 543
Self-citationAggregation-Induced Emission (AIE), Life and Health
Wang, H., Li, Q., Alam, P., Bai, H., Bhalla, V., Bryce, M. R., Cao, M., Chen, C., Chen, S., Chen, X., et al. (2023) · ACS Nano · doi:10.1021/acsnano.3c03925 · Cited by 385
Self-citationTian, Y., Chen, Z., Liu, S., Wu, F., Cao, W., Pang, D., & Xiong, H. (2023) · Angewandte Chemie International Edition · doi:10.1002/anie.202309768 · Cited by 57
Liu, D., He, Z., Gao, W., Shang, J., Yang, Y., Zhang, X., Li, X., Ma, H., & Shi, W. (2025) · Nature Communications · doi:10.1038/s41467-025-60241-2 · Cited by 32
Metadata
- Authors
- Liu, J., Zhang, W., Zhou, C., Li, M., Wang, X., Zhang, W., Liu, Z., Wu, L., James, T. D., Li, P., & Tang, B.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2022-07-06
- Volume
- 144
- Issue
- 30
- Pages
- 13586-13599
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W4284888274
- Cited by
- 205
- References
- 4
- FWCI
- 14.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.