Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 222

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Rapid Simultaneous Removal of Toxic Anions [HSeO3]−, [SeO3]2–, and [SeO4]2–, and Metals Hg2+, Cu2+, and Cd2+ by MoS42– Intercalated Layered Double Hydroxide

Ma, Lijiao, Islam, Saiful M., Xiao, Chengliang, Zhao, Jing, Liu, Hongyun, Yuan, Mengwei, Sun, Genban, Li, Huifeng, Ma, Shulan, Kanatzidis, Mercouri G.·2017·Journal of the American Chemical Society

Abstract

We demonstrate fast, highly efficient concurrent removal of toxic oxoanions of Se(VI) (SeO 4 2– ) and Se(IV) (SeO 3 2– /HSeO 3 – ) and heavy metal ions of Hg 2+, Cu 2+, and Cd 2+ by the MoS 4 2– intercalated Mg/Al layered double hydroxide (MgAl-MoS 4 -LDH, abbr. MoS 4 -LDH). Using the MoS 4 -LDH as a sorbent, we observe that the presence of Hg 2+ ions greatly promotes the capture of SeO 4 2–, while the three metal ions (Hg 2+, Cu 2+, Cd 2+ ) enable a remarkable improvement in the removal of SeO 3 2– /HSeO 3 – . For the pair Se(VI)+Hg 2+, the MoS 4 -LDH exhibits outstanding removal rates (>99.9%) for both Hg 2+ and Se(VI), compared to 81% removal for SeO 4 2– alone. For individual SeO 3 2– (without metal ions), 99.1% Se(IV) removal is achieved, while ≥99.9% removals are reached in the presence of Hg 2+, Cu 2+, and Cd 2+ . Simultaneously, the removal rates for these metal ions are also >99.9%, and nearly all concentrations of the elements can be reduced to <10 ppb, a limit acceptable for drinking water. The maximum sorption capacities for individual Se(VI) and Se(IV) are 85 and 294 mg/g, respectively. The 294 mg/g capacity for Se(IV) reaches a record value, placing the MoS 4 -LDH among the highest-capacity selenite adsorbing materials described to date. More interestingly, the presence of metal ions extremely accelerates the capture of the selenium oxoanions because of the reactions of the metal ions with the interlayer MoS 4 2– anions. The sorptions of Se(VI)+Hg and Se(IV)+M (M = Hg 2+, Cu 2+, Cd 2+ ) are exceptionally rapid, showing >99.5% removals for Hg 2+ within 1 min and ∼99.0% removal for Se(VI) within 30 min, as well as >99.5% removals for pairs Cu 2+ and Se(IV) within 10 min, and Cd 2+ and Se(IV) within 30 min. During the sorption of SeO 3 2– /HSeO 3 –, reduction of Se(IV) occurs to Se 0 caused by the S 2– sites in MoS 4 2– . Sorption kinetics for the oxoanions follows a pseudo-second-order model consistent with chemisorption. The intercalated material of MoS 4 -LDH is very promising as a highly effective filter for decontamination of water with toxic Se(IV)/Se(VI) oxoanions along with heavy metals such as Hg 2+, Cd 2+, and Cu 2+ .

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jacs.7b07123

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 222

Metadata

Authors
Ma, L., Islam, S. M., Xiao, C., Zhao, J., Liu, H., Yuan, M., Sun, G., Li, H., Ma, S., & Kanatzidis, M. G.
Venue
Journal of the American Chemical Society
Published
2017-08-30
Volume
139
Issue
36
Pages
12745-12757
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2742344561
Cited by
222
References
3
FWCI
9.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.