The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Cell-Penetrating Peptides Transport Noncovalently Linked Thermally Activated Delayed Fluorescence Nanoparticles for Time-Resolved Luminescence Imaging
Abstract
Luminescent probes and nanoparticles (NPs) with long excited state lifetimes are essential for time-resolved biological imaging. Generally, cell membranes are physiological barriers that could prevent the uptake of many unnatural compounds. It is still a big challenge to prepare biocompatible imaging agents with high cytomembrane permeability, especially for nonmetallic NPs with long-lived luminescence. Herein, an amphiphilic cell-penetrating peptide, F 6 G 6 (rR) 3 R 2, was designed to transport hydrophobic fluorophores across cellular barriers. Three classical thermally activated delayed fluorescence (TADF) molecules, 4CzIPN, NAI-DPAC, and BTZ-DMAC, could self-assemble into well-dispersed NPs with F 6 G 6 (rR) 3 R 2 in aqueous solution. These NPs showed low cytotoxicity and could penetrate membranes easily. Moreover, long-lived TADF enabled them to be used in time-resolved luminescence imaging in oxygenic environments. These findings greatly expanded the applications of cell-penetrating peptides for delivery of molecules and NPs by only noncovalent interactions, which were more flexible and easier than covalent modifications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recent advances in organic thermally activated delayed fluorescence materials
Yang, Z., Mao, Z., Xie, Z., Zhang, Y., Liu, S., Zhao, J., Xu, J., Chi, Z., & Aldred, M. P. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00368k · Cited by 2,395
Xiong, X., Song, F., Wang, J., Zhang, Y., Xue, Y., Sun, L., Jiang, N., Gao, P., Tian, L., & Peng, X. (2014) · Journal of the American Chemical Society · doi:10.1021/ja502292p · Cited by 326
Self-citationNi, F., Zhu, Z., Tong, X., Xie, M., Zhao, Q., Zhong, C., Zou, Y., & Yang, C. (2018) · Chemical Science · doi:10.1039/c8sc01485j · Cited by 142
Self-citationLi, T., Yang, D., Zhai, L., Wang, S., Zhao, B., Fu, N., Wang, L., Tao, Y., & Huang, W. (2017) · Advanced Science · doi:10.1002/advs.201600166 · Cited by 138
Cited by
Xie, J., Bi, Y., Zhang, H., Dong, S., Teng, L., Lee, R. J., & Yang, Z. (2020) · Frontiers in Pharmacology · doi:10.3389/fphar.2020.00697 · Cited by 466
Molecular Probes for Autofluorescence-Free Optical Imaging
Jiang, Y., & Pu, K. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00506 · Cited by 426
Cheng, H.-B., Li, Y., Tang, B. Z., & Yoon, J. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00326f · Cited by 393
Self-citationQi, S., Kim, S., Nguyen, V.-N., Kim, Y., Niu, G., Kim, G., Kim, S.-J., Park, S., & Yoon, J. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c15936 · Cited by 112
Luo, M., Li, X., Ding, L., Baryshnikov, G., Shen, S., Zhu, M., Zhou, L., Zhang, M., Lu, J., Ågren, H., et al. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202009077 · Cited by 89
Metadata
- Authors
- Zhu, Z., Tian, D., Gao, P., Wang, K., Li, Y., Shu, X., Zhu, J., & Zhao, Q.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-12-10
- Volume
- 140
- Issue
- 50
- Pages
- 17484-17491
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2904438646
- Cited by
- 170
- References
- 4
- FWCI
- 7.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.