Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 163

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

High-Performance n-Type PbSe–Cu2Se Thermoelectrics through Conduction Band Engineering and Phonon Softening

Zhou, Chongjian, Yu, Yuan, Lee, Yong Kyu, Cojocaru-Mirédin, Oana, Yoo, Byeongjun, Cho, Sung-Pyo, Im, Jino, Wuttig, Matthias, Hyeon, Taeghwan, Chung, In · 2018 · Journal of the American Chemical Society

Abstract

From a structural and economic perspective, tellurium-free PbSe can be an attractive alternative to its more expensive isostructural analogue of PbTe for intermediate temperature power generation. Here we report that PbSe 0.998 Br 0.002 -2%Cu 2 Se exhibits record high peak ZT 1.8 at 723 K and average ZT 1.1 between 300 and 823 K to date for all previously reported n- and p-type PbSe-based materials as well as tellurium-free n-type polycrystalline materials. These even rival the highest reported values for n-type PbTe-based materials. Cu 2 Se doping not only enhance charge transport properties but also depress thermal conductivity of n-type PbSe. It flattens the edge of the conduction band of PbSe, increases the effective mass of charge carriers, and enlarges the energy band gap, which collectively improve the Seebeck coefficient markedly. This is the first example of manipulating the electronic conduction band to enhance the thermoelectric properties of n-type PbSe. Concurrently, Cu 2 Se increases the carrier concentration with nearly no loss in carrier mobility, even increasing the electrical conductivity above ∼423 K. The resulting power factor is ultrahigh, reaching ∼21–26 μW cm –1 K –2 over a wide range of temperature from ∼423 to 723 K. Cu 2 Se doping substantially reduces the lattice thermal conductivity to ∼0.4 W m –1 K –1 at 773 K, approaching its theoretical amorphous limit. According to first-principles calculations, the achieved ultralow value can be attributed to remarkable acoustic phonon softening at the low-frequency region.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jacs.8b10448

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Zhou, C., Yu, Y., Lee, Y. K., Cojocaru-Mirédin, O., Yoo, B., Cho, S.-P., Im, J., Wuttig, M., Hyeon, T., & Chung, I.
Venue
Journal of the American Chemical Society
Published
2018-10-22
Volume
140
Issue
45
Pages
15535-15545
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2895813839
Cited by
163
References
2
FWCI
4.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.