The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Unimolecular Chemo-fluoro-luminescent Reporter for Crosstalk-Free Duplex Imaging of Hepatotoxicity
Abstract
Real-time multiplex imaging is imperative to biology and diagnosis but remains challenging for optical modality. Herein, a unimolecular chemo-fluoro-luminescent reporter (CFR) is synthesized for duplex imaging of drug-induced hepatotoxicity (DIH), a long-term medical concern. CFR simultaneously detects superoxide anion (O 2 •– ) and caspase-3 (casp3) through respective activation of its independent chemiluminescence and near-infrared fluorescence channels. Such a crosstalk-free duplex imaging capability of CFR enables longitudinal measurement of two correlated biomolecular events (oxidative stress and cellular apoptosis) during the progression of DIH, identifying O 2 •– as an earlier biomarker for detection of DIH both in vitro and in vivo. Moreover, CFR detects DIH 17.5 h earlier than histological changes. Thus, our study not only develops a sensitive optical reporter for early detection of DIH but also provides a general molecular design strategy for duplex imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Can the pharmaceutical industry reduce attrition rates?
Kola, I., & Landis, J. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1470 · Cited by 4,167
Cited by
Design of superior phototheranostic agents guided by Jablonski diagrams
Feng, G., Zhang, G.-Q., & Ding, D. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00671h · Cited by 783
J -Aggregates of Cyanine Dye for NIR-II in Vivo Dynamic Vascular Imaging beyond 1500 nm
Sun, C., Li, B., Zhao, M., Wang, S., Lei, Z., Lu, L., Zhang, H., Feng, L., Dou, C., Yin, D., et al. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b10043 · Cited by 582
Molecular Probes for Autofluorescence-Free Optical Imaging
Jiang, Y., & Pu, K. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00506 · Cited by 426
Self-citationHemicyanine‐Based Near‐Infrared Activatable Probes for Imaging and Diagnosis of Diseases
Zeng, Z., Liew, S. S., Wei, X., & Pu, K. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202107877 · Cited by 359
Self-citationDual-locked spectroscopic probes for sensing and therapy
Wu, L., Huang, J., Pu, K., & James, T. D. (2021) · Nature Reviews Chemistry · doi:10.1038/s41570-021-00277-2 · Cited by 328
Self-citation
Metadata
- Authors
- Cheng, P., Miao, Q., Li, J., Huang, J., Xie, C., & Pu, K.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-07-01
- Volume
- 141
- Issue
- 27
- Pages
- 10581-10584
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2953537318
- Cited by
- 234
- References
- 1
- FWCI
- 12.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Unimolecular Chemo-fluoro-luminescent Reporter for Crosstalk-Free Duplex Imaging of Hepatotoxicity. https://app.cochat.ai/papers/10.1021/jacs.9b02580
- The paper
- Cheng, P., Miao, Q., Li, J., Huang, J., Xie, C., & Pu, K. (2019). Unimolecular Chemo-fluoro-luminescent Reporter for Crosstalk-Free Duplex Imaging of Hepatotoxicity. Journal of the American Chemical Society. https://doi.org/10.1021/jacs.9b02580
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.