Cited by 66Luminescence and Fluorescent MaterialsNanoplatforms for cancer theranosticsMetal complexes synthesis and properties

The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.

Rhodium(I) Complex-Based Polymeric Nanomicelles in Water Exhibiting Coexistent Near-Infrared Phosphorescence Imaging and Anticancer Activity in Vivo

Open access
Wang, Jun, Nie, Jing-Jun, Guo, Pingxia, Yan, Zihao, Yu, Bingran, Bu, Weifeng·2020·Journal of the American Chemical Society

Abstract

Metal complexes that exhibit both near-infrared (NIR) phosphorescence imaging and chemotherapeutic activity would represent a novel class of anticancer drugs in clinical tumor treatment. In this work, a series of novel rodlike nanomicelles have been fabricated in water by coupling poly(ethylene oxide)- block -poly(sodium acrylate) and [Rh(C≡N-2,6-xylyl) 4 ] + ( 1 / 2 SO 4 ) − . These nanomicelles exhibit intense NIR phosphorescence and excellent stability. As revealed by in vivo NIR phosphorescence imaging data, the rodlike nanomicelle can selectively stain tumor sites with a long retention time. Moreover, the nanorods demonstrate effective anticancer activity by precisely killing tumor tissues without damaging healthy organs in vivo. To the best of our knowledge, this research provides the first example of metal-based complexes showing simultaneous NIR luminescence imaging and antitumor activity in vivo.

Overview

Integrity signals

Registry

Crossref · 10.1021/jacs.9b11013

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 45 references

Research works printed but not linked: 3

  1. Craciunescu G., 1989, Anticancer Res., 9, 781
  2. Craciunescu D. G., 1991, In Vivo, 5, 329
  3. Giraldi T., 1977, Cancer Res., 37, 2662

Cited by

Sorted by citations

Metadata

Authors
Wang, J., Nie, J.-J., Guo, P., Yan, Z., Yu, B., & Bu, W.
Affiliations
  • State Key Laboratory of Applied Organic Chemistry (CN)
  • State Key Laboratory of Chemical Resource Engineering (CN)
  • Chinese Academy of Sciences (CN)
Corresponding author
  • Yu, Bingran
  • Bu, Weifeng
Venue
Journal of the American Chemical Society
Published
2020-01-30
Volume
142
Issue
6
Pages
2709-2714
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W3003687332
Cited by
66
References
45
Citations by year
2026: 8 · 2025: 17 · 2024: 11 · 2023: 9 · 2022: 10 · 2021: 7 · 2020: 4
FWCI
2.92
Type
journal article
Language
en
Open access
Locations
  • Journal of the American Chemical Society (publishedVersion)
  • PubMed (publishedVersion)
  • Lanzhou University Institutional Repository (submittedVersion, cc-by-nc-sa)
  • Lanzhou University Institutional Repository (submittedVersion)
Funders
  • State Key Laboratory of Polymer Physics and Chemistry (2018-25)
  • State Key Laboratory of Supramolecular Structure and Materials (sklssm201903)
  • National Natural Science Foundation of China (21474044, 21674044)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Nanoplatforms for cancer theranostics
  • Health Sciences › Medicine › Oncology › Metal complexes synthesis and properties
Keywords
rhodium(I) complexes, polymeric micelles, anticancer activity, tumor targeting, in vivo tumor imaging, anticancer agents
MeSH terms
Animals, Antineoplastic Agents, Mice, Nude, Micelles, Polymers, Rhodium, Water, Spectroscopy, Near-Infrared, Xenograft Model Antitumor Assays, Nanostructures, Luminescence, Mice, Coordination Complexes

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review