To Cleave or Not To Cleave in XL-MS?
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Cross-linking mass spectrometry (XL-MS) is an efficient technique for uncovering structural features and interactions of the in-solution state of the proteins under investigation. Distance constraints obtained by this technique are highly complementary to classical structural biology approaches like X-ray crystallography and cryo-EM and have successfully been leveraged to shed light on protein structures of increasing size and complexity. To accomplish this, small reagents are used that typically incorporate two amine reactive moieties connected by a spacer arm and that can be applied in solution to protein structures of any size. Over the years, many reagents initially developed for different applications were adopted, and others were specifically developed for XL-MS. This has resulted in a vast array of options, making it difficult to make the right choice for specific experiments. Here, we delve into the previous decade of published XL-MS literature to uncover which workflows have been predominantly applied. We focus on application papers as these represent proof that biologically valid results can be extracted. This ignores some more recent approaches that did not have sufficient time to become more widely applied, for which we supply a separate discussion. From our selection, we extract information on the types of samples, cross-linking reagent, prefractionation, instruments, and data analysis, to highlight widely used workflows. All of the results are summarized in an easy-to-use flow chart defined by selection points resulting from our analysis. Although potentially biased by our own experiences, we expect this overview to be useful for novices stepping into this rapidly expanding field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kühlbrandt, W. (2014) · Science · doi:10.1126/science.1251652 · Cited by 1,325
Native mass spectrometry: a bridge between interactomics and structural biology
Heck, A. J. R. (2008) · Nature Methods · doi:10.1038/nmeth.1265 · Cited by 766
Self-citationA dual pressure linear ion trap orbitrap instrument with very high sequencing speed
Olsen, J. V., Schwartz, J. C., Griep-Raming, J., Nielsen, M. L., Damoc, E., Denisov, E., Lange, O., Remes, P., Taylor, D., Splendore, M., et al. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900375-mcp200 · Cited by 464
Structure of activated transcription complex Pol II–DSIF–PAF–SPT6
Vos, S. M., Farnung, L., Boehning, M., Wigge, C., Linden, A., Urlaub, H., & Cramer, P. (2018) · Nature · doi:10.1038/s41586-018-0440-4 · Cited by 432
The diverse and expanding role of mass spectrometry in structural and molecular biology
Lössl, P., van de Waterbeemd, M., & Heck, A. J. (2016) · The EMBO Journal · doi:10.15252/embj.201694818 · Cited by 222
Self-citationTang, X., & Bruce, J. E. (2010) · Molecular BioSystems · doi:10.1039/b920876c · Cited by 143
Cited by
Schnirch, L., Nadler-Holly, M., Siao, S.-W., Frese, C. K., Viner, R., & Liu, F. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c01273 · Cited by 53
Birklbauer, M. J., Müller, F., Geetha, S. S., Matzinger, M., Mechtler, K., & Dorfer, V. (2024) · Communications Chemistry · doi:10.1038/s42004-024-01386-x · Cited by 11
Thrombin activation of the factor XI dimer is a multi-staged process for each subunit
Barroeta, A. B., Albanese, P., Marquart, J. A., Meijers, J. C. M., & Scheltema, R. A. (2023) · doi:10.1101/2023.02.11.528103 · Cited by 1
Self-citation
Metadata
- Authors
- Steigenberger, B., Albanese, P., Heck, A. J. R., & Scheltema, R. A.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-12-27
- Volume
- 31
- Issue
- 2
- Pages
- 196-206
- ISSN
- 1044-0305 (ISSN-L)
- 1879-1123
- OpenAlex
- W2997275645
- Cited by
- 84
- References
- 6
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.