The DOI matches its Crossref record.
Adsorption Equilibria of CO2 on Zeolite 13X and Zeolite X/Activated Carbon Composite
Abstract
The adsorption equilibria of CO 2 on zeolite 13X and zeolite X/activated carbon composite (Zeocarbon) were measured by a static volumetric method. The equilibrium experiments were conducted at (273.15, 293.15, 313.15, 333.15, and 353.15) K and at pressures up to 102.0 kPa for zeolite 13X and 99.7 kPa for Zeocarbon. The experimental data obtained were correlated by the Toth, UNILAN, and Sips models, which are generally used for microporous adsorbents such as zeolites and activated carbon. The isosteric enthalpies of adsorption were calculated for CO 2 on both adsorbents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 12
- Kikkinides E. S., 1993, Ind. Eng. Chem. Res., 32, 2720
- Przepiorski J., 2002, Adsorption of Carbon Dioxide on Phenolic Resin-Based Carbon Spheres. Appl. Surf. Sci
- Ruthven D. M., 1984, Principles of Adsorption and Adsorption Process
- Choung J. H., 2001, J. Chem. Eng. Data, 46, 958, 10.1021/je000282i · DOI
- Ahmedna M., 2000, Bioresour. Technol., 71, 123
- Hyun S. H., 1982, J. Chem. Eng. Data, 27, 200, 10.1021/je00028a030 · DOI
- Valenzuela D. P., 1989, Adsorption Equilibrium Data Handbook
- Meredith J. M., 1967, J. Chem. Eng. Data, 12, 261, 10.1021/je60033a026 · DOI
- Berlier K., 1996, J. Chem. Eng. Data, 41, 1148, 10.1021/je960080f · DOI
- Toth J., 1984, Fundamentals of Adsorption, 665
- Do D. D., 1998, Adsorption Analysis
- Hill T. L, 1949, J. Chem. Phys., 17, 535
Cited by
Direct Air Capture of CO2 by Physisorbent Materials
Kumar, A., Madden, D. G., Lusi, M., Chen, K., Daniels, E. A., Curtin, T., Perry, J. J., & Zaworotko, M. J. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201506952 · Cited by 588
Advances in principal factors influencing carbon dioxide adsorption on zeolites
Bonenfant, D., Kharoune, M., Niquette, P., Mimeault, M., & Hausler, R. (2008) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/9/1/013007 · Cited by 351
Karimi, M., Shirzad, M., Silva, J. A. C., & Rodrigues, A. E. (2022) · Journal of CO2 Utilization · doi:10.1016/j.jcou.2022.101890 · Cited by 237
Adsorption of CO2on Zeolite 13X and Activated Carbon with Higher Surface Area
Zhang, Z., Zhang, W., Chen, X., Xia, Q., & Li, Z. (2010) · Separation Science and Technology · doi:10.1080/01496390903571192 · Cited by 146
Fixed bed adsorption as affected by thermodynamics and kinetics: yellow tuff for CO2 capture
Ammendola, P., Raganati, F., Chirone, R., & Miccio, F. (2020) · Powder Technology · doi:10.1016/j.powtec.2020.06.075 · Cited by 88
Metadata
- Authors
- Lee, J.-S., Kim, J.-H., Kim, J.-T., Suh, J.-K., Lee, J.-M., & Lee, C.-H.
- Venue
- Journal of Chemical & Engineering Data
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-06-26
- Volume
- 47
- Issue
- 5
- Pages
- 1237-1242
- ISSN
- 0021-9568 (ISSN-L)
- 1520-5134
- OpenAlex
- W1999343478
- Cited by
- 260
- References
- 0
- FWCI
- 2.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adsorption Equilibria of CO2 on Zeolite 13X and Zeolite X/Activated Carbon Composite. https://app.cochat.ai/papers/10.1021/je020050e
- The paper
- Lee, J.-S., Kim, J.-H., Kim, J.-T., Suh, J.-K., Lee, J.-M., & Lee, C.-H. (2002). Adsorption Equilibria of CO2 on Zeolite 13X and Zeolite X/Activated Carbon Composite. Journal of Chemical & Engineering Data. https://doi.org/10.1021/je020050e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.