The DOI matches its Crossref record.
Effect of Water on the Electrochemical Window and Potential Limits of Room-Temperature Ionic Liquids
Abstract
The effect of water content on room-temperature ionic liquids (RTILs) was studied by Karl Fischer titration and cyclic voltammetry in the following ionic liquids: tris(P-hexyl)tetradecylphosphonium trifluorotris(pentafluoroethyl)phosphate [P 14,6,6,6 ][NTf 2 ], N -butyl- N -methyl-pyrrolidinium bis(trifluoromethylsulfonyl)imide [C 4 mpyrr][NTf 2 ], 1-hexyl-3-methylimidazolium tris(perfluoroethyl)trifluorophosphate [C 6 mim][FAP], 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide [C 4 mim][NTf 2 ], 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide [C 4 dmim][NTf 2 ], N -hexyltriethylammonium bis(trifluoromethylsolfonyl)imide [N 6,2,2,2 ][NTf 2 ], 1-butyl-3-methylimidazolium hexafluorophosphate [C 4 mim][PF 6 ], 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide [C 2 mim][NTf 2 ], 1-butyl-3-methylimidazolium tetrafluoroborate [C 4 mim][BF 4 ], 1-hexyl-3-methylimidazolium iodide [C 4 mim][I], 1-butyl-3-methylimidazolium trifluoromethylsulfonate [C 4 mim][OTf], and 1-hexyl-3-methylimidazolium chloride [C 6 mim][Cl]. In addition, electrochemically relevant properties such as viscosity, conductivity, density, and melting point of RTILs are summarized from previous literature and are discussed. Karl Fisher titrations were carried out to determine the water content of RTILs for vacuum-dried, atmospheric, and wet samples. The anion in particular was found to affect the level of water uptake. The hydrophobicity of the anions adhered to the following trend: [FAP] − > [NTf 2 ] − > [PF 6 ] − > [BF 4 ] − > halides. Cyclic voltammetry shows that an increase in water content significantly narrows the electrochemical window of each ionic liquid. The electrochemical window decreases in the following order: vacuum-dried > atmospheric > wet at 298 K > 318 K > 338 K. The anodic and cathodic potentials vs ferrocene internal reference are also listed under vacuum-dried and atmospheric conditions. The data obtained may aid the selection of a RTIL for use as a solvent in electrochemical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ionic liquids and catalysis: Recent progress from knowledge to applications
Olivier-Bourbigou, H., Magna, L., & Morvan, D. (2010) · Applied Catalysis A: General · doi:10.1016/j.apcata.2009.10.008 · Cited by 1,639
The hydrogen evolution reaction: from material to interfacial descriptors
Dubouis, N., & Grimaud, A. (2019) · Chemical Science · doi:10.1039/c9sc03831k · Cited by 962
Ionic Liquids-Based Extraction: A Promising Strategy for the Advanced Nuclear Fuel Cycle
Sun, X., Luo, H., & Dai, S. (2012) · Chemical Reviews · doi:10.1021/cr200193x · Cited by 852
Yao, C., Pitner, W. R., & Anderson, J. L. (2009) · Analytical Chemistry · doi:10.1021/ac900719m · Cited by 167
Go, G.-T., Lee, Y., Seo, D.-G., Pei, M., Lee, W., Yang, H., & Lee, T.-W. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000012 · Cited by 125
Metadata
- Authors
- O’Mahony, A. M., Silvester, D. S., Aldous, L., Hardacre, C., & Compton, R. G.
- Venue
- Journal of Chemical & Engineering Data
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-11-07
- Volume
- 53
- Issue
- 12
- Pages
- 2884-2891
- ISSN
- 0021-9568 (ISSN-L)
- 1520-5134
- OpenAlex
- W2075565110
- Cited by
- 574
- References
- 0
- FWCI
- 10.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Water on the Electrochemical Window and Potential Limits of Room-Temperature Ionic Liquids. https://app.cochat.ai/papers/10.1021/je800678e
- The paper
- O’Mahony, A. M., Silvester, D. S., Aldous, L., Hardacre, C., & Compton, R. G. (2008). Effect of Water on the Electrochemical Window and Potential Limits of Room-Temperature Ionic Liquids. Journal of Chemical & Engineering Data. https://doi.org/10.1021/je800678e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.