Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 574

The DOI matches its Crossref record.

Effect of Water on the Electrochemical Window and Potential Limits of Room-Temperature Ionic Liquids

O’Mahony, Aoife M., Silvester, Debbie S., Aldous, Leigh, Hardacre, Christopher, Compton, Richard G.·2008·Journal of Chemical & Engineering Data

Abstract

The effect of water content on room-temperature ionic liquids (RTILs) was studied by Karl Fischer titration and cyclic voltammetry in the following ionic liquids: tris(P-hexyl)tetradecylphosphonium trifluorotris(pentafluoroethyl)phosphate [P 14,6,6,6 ][NTf 2 ], N -butyl- N -methyl-pyrrolidinium bis(trifluoromethylsulfonyl)imide [C 4 mpyrr][NTf 2 ], 1-hexyl-3-methylimidazolium tris(perfluoroethyl)trifluorophosphate [C 6 mim][FAP], 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide [C 4 mim][NTf 2 ], 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide [C 4 dmim][NTf 2 ], N -hexyltriethylammonium bis(trifluoromethylsolfonyl)imide [N 6,2,2,2 ][NTf 2 ], 1-butyl-3-methylimidazolium hexafluorophosphate [C 4 mim][PF 6 ], 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide [C 2 mim][NTf 2 ], 1-butyl-3-methylimidazolium tetrafluoroborate [C 4 mim][BF 4 ], 1-hexyl-3-methylimidazolium iodide [C 4 mim][I], 1-butyl-3-methylimidazolium trifluoromethylsulfonate [C 4 mim][OTf], and 1-hexyl-3-methylimidazolium chloride [C 6 mim][Cl]. In addition, electrochemically relevant properties such as viscosity, conductivity, density, and melting point of RTILs are summarized from previous literature and are discussed. Karl Fisher titrations were carried out to determine the water content of RTILs for vacuum-dried, atmospheric, and wet samples. The anion in particular was found to affect the level of water uptake. The hydrophobicity of the anions adhered to the following trend: [FAP] − > [NTf 2 ] − > [PF 6 ] − > [BF 4 ] − > halides. Cyclic voltammetry shows that an increase in water content significantly narrows the electrochemical window of each ionic liquid. The electrochemical window decreases in the following order: vacuum-dried > atmospheric > wet at 298 K > 318 K > 338 K. The anodic and cathodic potentials vs ferrocene internal reference are also listed under vacuum-dried and atmospheric conditions. The data obtained may aid the selection of a RTIL for use as a solvent in electrochemical applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/je800678e

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Metadata

Authors
O’Mahony, A. M., Silvester, D. S., Aldous, L., Hardacre, C., & Compton, R. G.
Venue
Journal of Chemical & Engineering Data
Published
2008-11-07
Volume
53
Issue
12
Pages
2884-2891
ISSN
  • 0021-9568 (ISSN-L)
  • 1520-5134
OpenAlex
W2075565110
Cited by
574
References
0
FWCI
10.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of Water on the Electrochemical Window and Potential Limits of Room-Temperature Ionic Liquids. https://app.cochat.ai/papers/10.1021/je800678e
The paper
O’Mahony, A. M., Silvester, D. S., Aldous, L., Hardacre, C., & Compton, R. G. (2008). Effect of Water on the Electrochemical Window and Potential Limits of Room-Temperature Ionic Liquids. Journal of Chemical & Engineering Data. https://doi.org/10.1021/je800678e

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.