Ionic Liquids Containing the Tris(pentafluoroethyl)trifluorophosphate Anion: a New Class of Highly Selective and Ultra Hydrophobic Solvents for the Extraction of Polycyclic Aromatic Hydrocarbons Using Single Drop Microextraction
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
A new class of ionic liquids (ILs) containing the tris(pentafluoroethyl)trifluorophosphate (FAP) anion are paired with imidazolium, phosphonium, and pyrrolidinium cations and used as extraction solvents in direct immersion single drop microextraction (SDME) studies coupled to high performance liquid chromatography (HPLC). The selectivity and sensitivity of the extraction method can be tuned and manipulated by varying the cationic component of the IL, thereby providing larger enrichment factors for a variety of analytes, including polycyclic aromatic hydrocarbons (PAHs). Compared to other hydrophobic ILs containing the hexafluorophosphate (PF(6)(-)) and bis[(trifluoromethyl)sulfonyl]imide (NTf(2)(-)) anions, FAP-based ILs are significantly more hydrophobic and hydrolytically stable permitting them to be used in the sampling of large volumes of aqueous solutions without dissolution or loss of the IL. The highest enrichment factors were obtained with the trihexyl(tetradecyl)phosphonium FAP ([PH(3)T] [FAP]) IL for compounds with high molecular weight and fused rings while high enrichment factors were obtained for smaller, more polar molecules using the 1-hexyl-3-methylimidazolium FAP ([HMIM] [FAP]) IL. The detection limits for nine studied PAHs ranged from 0.1 to 0.6, 0.03 to 0.4, 0.04 to 0.7 and 0.1 to 1.2 microg L(-1) for [HMIM] [FAP], [PH(3)T] [FAP], 1-butyl-1-methylpyrrolidinium FAP ([BMPL] [FAP]), and 1-(6-amino-hexyl)-1-methylpyrrolidinium FAP ([HNH(2)MPL] [FAP]), respectively. The reproducibility of the extraction method at 20 degrees C using the FAP-based ILs was in the range of 1.5-9.4%. Three real water samples including tap water, creek water, and river water were analyzed and yielded recoveries ranging from 79-114%.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This study demonstrated that the application of SDME for analysis of PAHs had high efficiency [77].”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [77]
Citations
Cites
CO2 Capture by a Task-Specific Ionic Liquid
Bates, E. D., Mayton, R. D., Ntai, I., & Davis, J. H. (2002) · Journal of the American Chemical Society · doi:10.1021/ja017593d · Cited by 2,270
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Pedersen-Bjergaard, S., & Rasmussen, K. E. (1999) · Analytical Chemistry · doi:10.1021/ac990055n · Cited by 1,245
Ionic liquids are not always green: hydrolysis of 1-butyl-3-methylimidazolium hexafluorophosphate
Swatloski, R. P., Holbrey, J. D., & Rogers, R. D. (2003) · Green Chemistry · doi:10.1039/b304400a · Cited by 982
Electrodeposition from Ionic Liquids
(2008) · Wiley eBooks · doi:10.1002/9783527622917 · Cited by 804
Improving Carbon Dioxide Solubility in Ionic Liquids
Muldoon, M. J., Aki, S. N. V. K., Anderson, J. L., Dixon, J. K., & Brennecke, J. F. (2007) · The Journal of Physical Chemistry B · doi:10.1021/jp071897q · Cited by 800
Self-citationHe, Y., & Lee, H. K. (1997) · Analytical Chemistry · doi:10.1021/ac970242q · Cited by 681
Developments in liquid-phase microextraction
Psillakis, E., & Kalogerakis, N. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)01007-0 · Cited by 608
Effect of Water on the Electrochemical Window and Potential Limits of Room-Temperature Ionic Liquids
O’Mahony, A. M., Silvester, D. S., Aldous, L., Hardacre, C., & Compton, R. G. (2008) · Journal of Chemical & Engineering Data · doi:10.1021/je800678e · Cited by 574
Use of Ionic Liquids for Liquid-Phase Microextraction of Polycyclic Aromatic Hydrocarbons
Liu, J.-F., Jiang, G.-B., Chi, Y.-G., Cai, Y.-Q., Zhou, Q.-X., & Hu, J.-T. (2003) · Analytical Chemistry · doi:10.1021/ac034506m · Cited by 484
Research works printed but not linked: 4
- Chrobok A., 2007, Pol. J. Chem., 81, 337
- Gammon M. D., 2002, Cancer Epidemiol. Biomarkers Prev., 11, 677
- Li D., 1996, Cancer Res., 56, 287
- Froehlich, U.Chirality and Ionic Liquids, PhD. dissertation, Queen’s University of Belfast, May 2005.
Cited by
Dai, Y., Witkamp, G.-J., Verpoorte, R., & Choi, Y. H. (2013) · Analytical Chemistry · doi:10.1021/ac400432p · Cited by 678
“Synthetic ILs possess attractive properties such as negligible volatility, tunable physicochemical properties (Huddleston et al., 2001), ability to dissolve a wide spectrum of solutes, and special tailor-made selectivity in extraction and separation (Yao et al., 2009; Ragonese et al., 2011).”
BackgroundIonic liquids and deep eutectic mixtures: Sustainable solvents for extraction processes
Pena‐Pereira, F., & Namieśnik, J. (2014) · ChemSusChem · doi:10.1002/cssc.201301192 · Cited by 432
Green Solvents in Carbohydrate Chemistry: From Raw Materials to Fine Chemicals
Farrán, A., Cai, C., Sandoval, M., Xu, Y., Liu, J., Hernáiz, M. J., & Linhardt, R. J. (2015) · Chemical Reviews · doi:10.1021/cr500719h · Cited by 393
Green aspects, developments and perspectives of liquid phase microextraction techniques
Spietelun, A., Marcinkowski, Ł., de la Guardia, M., & Namieśnik, J. (2014) · Talanta · doi:10.1016/j.talanta.2013.10.050 · Cited by 333
Single drop microextraction—Development, applications and future trends
Jeannot, M. A., Przyjazny, A., & Kokosa, J. M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.10.089 · Cited by 276
Metadata
- Authors
- Yao, C., Pitner, W. R., & Anderson, J. L.
- Affiliations
- University of Toledo (US)
- Corresponding author
- Anderson, Jared L.
- ORCID
- Anderson, Jared L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-05-06
- Volume
- 81
- Issue
- 12
- Pages
- 5054-5063
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2040862406
- Cited by
- 167
- References
- 30
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 4 · 2022: 6 · 2021: 6 · 2020: 12 · 2019: 9 · 2018: 5 · 2017: 7 · 2016: 8 · 2015: 20 · 2014: 15 · 2013: 11 · 2012: 24
- FWCI
- 19.53
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Ionic liquids properties and applications
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Keywords
- ionic liquids, polycyclic aromatic hydrocarbons, single-drop microextraction, hydrophobic solvents, extraction selectivity, enrichment factor, cation effects, phosphonium ionic liquids, imidazolium ionic liquids, pyrrolidinium ionic liquids, water sample analysis, hydrolytic stability, tap water
- MeSH terms
- Chromatography, High Pressure Liquid, Fluorocarbons, Hydrocarbons, Fluorinated, Polycyclic Aromatic Hydrocarbons, Solvents, Spectrometry, Fluorescence, Time Factors, Reproducibility of Results, Sample Size, Ionic Liquids, Hydrophobic and Hydrophilic Interactions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ionic Liquids Containing the Tris(pentafluoroethyl)trifluorophosphate Anion: a New Class of Highly Selective and Ultra Hydrophobic Solvents for the Extraction of Polycyclic Aromatic Hydrocarbons Using Single Drop Microextraction. https://app.cochat.ai/papers/10.1021/ac900719m
- The paper
- Yao, C., Pitner, W. R., & Anderson, J. L. (2009). Ionic Liquids Containing the Tris(pentafluoroethyl)trifluorophosphate Anion: a New Class of Highly Selective and Ultra Hydrophobic Solvents for the Extraction of Polycyclic Aromatic Hydrocarbons Using Single Drop Microextraction. Analytical Chemistry. https://doi.org/10.1021/ac900719m
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.