CoChat

Determination of Octanol−Air Partition Coefficients (KOA) of Fluorotelomer Acrylates, Perfluoroalkyl Sulfonamids, and Perfluoroalkylsulfonamido Ethanols

Dreyer, Annekatrin, Langer, Vera, Ebinghaus, Ralf · 2009 · Journal of Chemical & Engineering Data
Cited by 33

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Octanol−air partition coefficients ( K OA ) for three fluorotelomer acrylates (6:2 FTA, 8:2 FTA, 10:2 FTA), two perfluoroalkyl sulfonamides ( n -methyl perfluorooctane sulfonamide (MeFOSA), n -ethyl perfluorooctane sulfonamide (EtFOSA)), and two perfluoroalkyl sulfonamido ethanols ( n -methyl perfluorooctane sulfonamido ethanol (MeFOSE), n -ethyl perfluorooctane sulfonamido ethanol (EtFOSE)) were determined over a temperature range from (278 to 313) K using a modified generator column method. The K OA values were calculated as the ratio of the target analyte concentrations in octanol to the target analyte concentrations in octanol saturated air. Calibrated log K OA values at 298 K ranged from 4.5 (6:2 FTA) to 6.7 (EtFOSE). Log K OA values decreased with increasing temperature and increased in the order of 6:2 FTA, 8:2 FTA, 10:2 FTA, MeFOSA, MeFOSE, EtFOSA, EtFOSE. The combined uncertainty of the method applied ranged from 5.1 % (6:2 FTA) to 17.6 % (MeFOSA). The relative extended uncertainty ( P = 95 %) ranged from 11.6 % (6:2 FTA) to 39.8 % (MeFOSA), respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/je900082g

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 33

Metadata

Authors
Dreyer, A., Langer, V., & Ebinghaus, R.
Venue
Journal of Chemical & Engineering Data
Published
2009-10-01
Volume
54
Issue
11
Pages
3022-3025
ISSN
  • 0021-9568 (ISSN-L)
  • 1520-5134
OpenAlex
W1998557126
Cited by
33
References
5
FWCI
1.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.