The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Classification of Kinase Inhibitors Using a Bayesian Model
Abstract
The use of Bayesian statistics to model both general (multifamily) and specific (single-target) kinase inhibitors is investigated. The approach demonstrates an alternative to current computational methods applied to heterogeneous structure/activity data sets. This approach operates rapidly and is readily modifiable as required. A generalized model generated using inhibitor data from multiple kinase classes shows meaningful enrichment for several specific kinase targets. Such an approach can be used to prioritize compounds for screening or to optimally select compounds from third-party data collections. The observed benefit of the approach is finding compounds that are not structurally related to known actives, or novel targets for which there is not enough information to build a specific kinase model. The general kinase model described was built from a basis of mostly tyrosine kinase inhibitors, with some serine/threonine inhibitors; all the test cases used in prediction were also on tyrosine kinase targets. Confirming the applicability of this technique to other kinase families will be determined once those biological assays become available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cramer, R. D., Patterson, D. E., & Bunce, J. D. (1988) · Journal of the American Chemical Society · doi:10.1021/ja00226a005 · Cited by 3,931
Cited by
DeepTox: toxicity prediction using deep learning
Mayr, A., Klambauer, G., Unterthiner, T., & Hochreiter, S. (2016) · Frontiers in Environmental Science · doi:10.3389/fenvs.2015.00080 · Cited by 1,081
Jiang, D., Wu, Z., Hsieh, C.-Y., Chen, G., Liao, B., Wang, Z., Shen, C., Cao, D., Wu, J., & Hou, T. (2021) · Journal of Cheminformatics · doi:10.1186/s13321-020-00479-8 · Cited by 664
Large-scale comparison of machine learning methods for drug target prediction on ChEMBL
Mayr, A., Klambauer, G., Unterthiner, T., Steijaert, M., Wegner, J. K., Ceulemans, H., Clevert, D.-A., & Hochreiter, S. (2018) · Chemical Science · doi:10.1039/c8sc00148k · Cited by 584
Vatansever, S., Schlessinger, A., Wacker, D., Kaniskan, H. Ü., Jin, J., Zhou, M., & Zhang, B. (2021) · Medicinal Research Reviews · doi:10.1002/med.21764 · Cited by 429
Open Source Bayesian Models. 1. Application to ADME/Tox and Drug Discovery Datasets
Clark, A. M., Dole, K., Coulon-Spektor, A., McNutt, A., Grass, G., Freundlich, J. S., Reynolds, R. C., & Ekins, S. (2015) · Journal of Chemical Information and Modeling · doi:10.1021/acs.jcim.5b00143 · Cited by 114
Metadata
- Authors
- Xia, X., Maliski, E. G., Gallant, P., & Rogers, D.
- Venue
- Journal of Medicinal Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-08-01
- Volume
- 47
- Issue
- 18
- Pages
- 4463-4470
- ISSN
- 0022-2623 (ISSN-L)
- 1520-4804
- OpenAlex
- W1978253274
- Cited by
- 352
- References
- 1
- FWCI
- 6.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Classification of Kinase Inhibitors Using a Bayesian Model. https://app.cochat.ai/papers/10.1021/jm0303195
- The paper
- Xia, X., Maliski, E. G., Gallant, P., & Rogers, D. (2004). Classification of Kinase Inhibitors Using a Bayesian Model. Journal of Medicinal Chemistry. https://doi.org/10.1021/jm0303195
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.