The DOI matches its Crossref record.
Ion and Water Transport Characteristics of Perfluorosulfonated Ionomer Membranes with H+ and Alkali Metal Cations
Abstract
Ion and water transport characteristics of Nafion ionomer membranes were investigated systematically in the mixed cation form of H + and various kinds of alkali metal cation systems, which were prepared by equilibrating the membranes in the mixtures of HCl and alkali chloride in aqueous solutions of various mixing ratios. The membrane cationic composition showed that cations of larger atomic number had a higher affinity to sulfonic acid groups but less water content in the membrane than those of smaller atomic numbers. The net ionic conductivity was decreased, in any case, by the presence of alkali metal cations in the membrane. Different kinds of the interaction mode among cations were observed between H/Li or H/Na systems and H/K, H/Rb, or H/Cs systems. The interaction between alkali metal cations appeared to increase as the atomic number of the alkali metal cation increased. The water transference coefficient (electro-osmosis drag coefficient) increased from 2.5 to more than 10 by the presence of alkali metal cations. In the mixed systems, these cations were found to cause less water molecule drag than in the case of individual ions, in the presence of H + ion. Overall, the transport characteristics of H + and alkali metal cations influenced each other by way of the water molecules when they coexist in the membrane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
New Insights into Perfluorinated Sulfonic-Acid Ionomers
Kusoglu, A., & Weber, A. Z. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00159 · Cited by 2,432
Selectivity of ion exchange membranes: A review
Luo, T., Abdu, S., & Wessling, M. (2018) · Journal of Membrane Science · doi:10.1016/j.memsci.2018.03.051 · Cited by 1,123
Feng, Q., Yuan, X., Liu, G., Wei, B., Zhang, Z., Li, H., & Wang, H. (2017) · Journal of Power Sources · doi:10.1016/j.jpowsour.2017.09.006 · Cited by 776
Impact of impurities on water electrolysis: a review
Becker, H., Murawski, J., Shinde, D. V., Stephens, I. E. L., Hinds, G., & Smith, G. (2023) · Sustainable Energy & Fuels · doi:10.1039/d2se01517j · Cited by 366
Properties of Nafion® NR-211 membranes for PEMFCs
Peron, J., Mani, A., Zhao, X., Edwards, D., Adachi, M., Soboleva, T., Shi, Z., Xie, Z., Navessin, T., & Holdcroft, S. (2010) · Journal of Membrane Science · doi:10.1016/j.memsci.2010.03.025 · Cited by 352
Xiang, Y., Lu, S., & Jiang, S. P. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35048c · Cited by 277
Adachi, M., Navessin, T., Xie, Z., Frisken, B., & Holdcroft, S. (2009) · Journal of The Electrochemical Society · doi:10.1149/1.3116922 · Cited by 79
Mathematical Modelling of Cation Contamination in a Proton‐exchange Membrane
Weber, A. Z., & Delacourt, C. (2008) · Fuel Cells · doi:10.1002/fuce.200800044 · Cited by 49
Metadata
- Authors
- Okada, T., Satou, H., Okuno, M., & Yuasa, M.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-01-17
- Volume
- 106
- Issue
- 6
- Pages
- 1267-1273
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2045715146
- Cited by
- 208
- References
- 0
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.