The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
FTIR Study of CO Adsorption on Ni−ZSM-5
Abstract
Adsorption of CO on Ni−ZSM-5 reveals the existence of two kinds of Ni 2+ ions, with the respective stretching frequencies being at 2220 and 2212 cm -1 . The carbonyl complexes are resistant to evacuation at room temperature, which is explained by the high electrophilicity of cations in a ZSM matrix. At 85 K and in the presence of CO, part of the Ni 2+ −CO species are converted into Ni 2+ (CO) 2 dicarbonyls (2204 cm -1 ) which are characterized by a very low stability and easily lose one of their CO ligands. Interaction of Ni−ZSM-5 with CO at 673−773 K results in a preferential reduction of the Ni 2+ ions which form the carbonyls characterized by the band at 2220 cm -1 . CO adsorption at room temperature on the reduced sample leads to the formation of Ni + (CO) 2 gem dicarbonyls (ν s at 2136 cm -1 and ν as at 2092 cm -1 ) which are converted, during evacuation, to linear Ni + −CO species (2109 cm -1 ). The dicarbonyl structure is proved by 12 CO− 13 CO coadsorption, and the mixed Ni + ( 12 CO)( 13 CO) species are characterized by ν( 12 CO) at 2123 cm -1 and ν( 13 CO) at 2058 cm -1 . At low temperature, a third CO molecule is coordinated to the Ni + cations, thus producing tricarbonyls (2156, 2124, and 2109 cm -1 ). The latter species lose one of their CO ligands during evacuation at 85 K and are converted back into dicarbonyls. The Ni + sites are easily oxidized in the presence of O 2 . However, the Ni 2+ ions produced differ in properties from the initially deposited cations and are easily reduced to Ni + even at ambient temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shannon, R. D. (1976) · Acta Crystallographica Section A · doi:10.1107/s0567739476001551 · Cited by 66,145
Cited by
Characterization of oxide surfaces and zeolites by carbon monoxide as an IR probe molecule
Hadjiivanov, K. I., & Vayssilov, G. N. (2002) · Advances in Catalysis · doi:10.1016/s0360-0564(02)47008-3 · Cited by 1,086
Self-citationSynthesis of Flower-Like NiO and Effects of Morphology on Its Catalytic Properties
Zhao, B., Ke, X.-K., Bao, J.-H., Wang, C.-L., Dong, L., Chen, Y.-W., & Chen, H.-L. (2009) · The Journal of Physical Chemistry C · doi:10.1021/jp904186k · Cited by 315
Importance of Size and Distribution of Ni Nanoparticles for the Hydrodeoxygenation of Microalgae Oil
Song, W., Zhao, C., & Lercher, J. A. (2013) · Chemistry – A European Journal · doi:10.1002/chem.201301005 · Cited by 154
Metadata
- Authors
- Hadjiivanov, K., Knözinger, H., & Mihaylov, M.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-02-19
- Volume
- 106
- Issue
- 10
- Pages
- 2618-2624
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2089072035
- Cited by
- 160
- References
- 1
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.