The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Dynamic Solvation in Room-Temperature Ionic Liquids
Abstract
The dynamic solvation of the fluorescent probe, coumarin 153, is measured in five room-temperature ionic liquids using different experimental techniques and methods of data analysis. With time-resolved stimulated-emission and time-correlated single-photon counting techniques, it is found that the solvation is comprised of an initial rapid component of ∼55 ps. In all the solvents, half or more of the solvation is completed within 100 ps. The remainder of the solvation occurs on a much longer time scale. The emission spectra of coumarin 153 are nearly superimposable at all temperatures in a given solvent unless they are obtained using the supercooled liquid, suggesting that the solvents have an essentially glassy nature. The physical origin of the two components is discussed in terms of the polarizability of the organic cation for the faster one and the relative diffusional motion of the cations and the anions for the slower one. A comparison of the solvation response functions obtained from single-wavelength and from spectral-reconstruction measurements is provided. Preliminary fluorescence-upconversion measurements are presented against which the appropriateness of the single-wavelength method for constructing solvation correlation functions and the use of stimulated-emission measurements is considered. These measurements are consistent with the trends mentioned above, but a comparison indicates that the presence of one or more excited states distorts the stimulated-emission kinetics such that they do not perfectly reproduce the spontaneous emission data. Fluorescence-upconversion results indicate an initial solvation component on the order of ∼7 ps.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Air and water stable 1-ethyl-3-methylimidazolium based ionic liquids
Wilkes, J. S., & Zaworotko, M. J. (1992) · Journal of the Chemical Society, Chemical Communications · doi:10.1039/c39920000965 · Cited by 1,883
Cited by
Room-Temperature Ionic Liquids: Solvents for Synthesis and Catalysis. 2
Hallett, J. P., & Welton, T. (2011) · Chemical Reviews · doi:10.1021/cr1003248 · Cited by 12,578
Understanding Ionic Liquids at the Molecular Level: Facts, Problems, and Controversies
Weingärtner, H. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200604951 · Cited by 1,543
Ionic liquids in analytical chemistry
Sun, P., & Armstrong, D. W. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.12.007 · Cited by 727
Self-citationWakai, C., Oleinikova, A., Ott, M., & Weingärtner, H. (2005) · The Journal of Physical Chemistry B · doi:10.1021/jp053946+ · Cited by 531
Ionic Liquids in Analytical Chemistry
Anderson, J. L., Armstrong, D. W., & Wei, G.-T. (2006) · Analytical Chemistry · doi:10.1021/ac069394o · Cited by 467
Self-citation
Metadata
- Authors
- Chowdhury, P. K., Halder, M., Sanders, L., Calhoun, T., Anderson, J. L., Armstrong, D. W., Song, X., & Petrich, J. W.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-06-02
- Volume
- 108
- Issue
- 29
- Pages
- 10245-10255
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2094054609
- Cited by
- 201
- References
- 1
- FWCI
- 14.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.